Inspections for the day of: Monday, June 24, 2019.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-02160 Rough-in6/24/20196/24/20196/24/2019 3:56:40 PMPFAIL
Phone #: ###-#### Inspection requested via web by Aaron Toomey
- CSST gas line needs approved manufactures nail plates installed
- tankless water heater vent needs to be approved materials
- need to see a 5lb flue pressure test
MEC19-02160 Pressure Test6/24/20196/24/20196/24/2019 3:46:41 PMPPASS
Phone #: ###-#### Inspection requested via web by Aaron Toomey
- 20lb gas pressure test ok
MEC19-02277 Final6/24/20196/24/20196/24/2019 3:04:50 PMPPASS
Inspection requested via web by Margie Rowe
- final ok
MEC19-02185 Final6/24/20196/24/20196/24/2019 3:04:35 PMPPASS
Inspection requested via web by Margie Rowe
- final ok
MEC19-02449 Final6/21/20196/24/20196/24/2019 2:50:59 PMPFAIL
Please call Beth prior to heading out. ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
- line set insulation is too close to single wall water heater vent
- need to see both upstairs and down stairs CO detectors installed near bedrooms
MEC19-01742 Rough-in6/24/20196/24/20196/24/2019 2:35:01 PMPPASS
Please call me a head of showing up incase I am able to meet you there.
Approved manual j will be sitting on the furnace in the bigger room in the garage.

Thank you Phone #: ###-#### Inspection requested via web by Geff Blecha
- R/I ok
MEC19-02657 Final6/24/20196/24/20196/24/2019 2:01:37 PMPPASS
Please call Ray about 15 minutes prior to inspection so he can get home from work. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace ac coil co ok
MEC19-02692 Rough-in6/23/20196/24/20196/24/2019 1:43:47 PMPPART
Please call James at ###-#### with any questions, thanks. Inspection requested via web by 4 Seasons
- range vent ok
- supply run in basment might be moved homeowner doesn't want to lower ceilings to cover duct work
MEC19-02618 Final6/21/20196/24/20196/24/2019 11:23:18 AMAFAIL
CONTACT DAN FOR QUESTIONS - ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- need to see electrical permit pulled for new ductless split
MEC19-02679 Final6/21/20196/24/20196/24/2019 11:04:02 AMAFAIL
Phone #: ###-#### Inspection requested via web by Marisa Hone
- need to witness 5lb flue pressure test
- need to connect combustion air vent to furnace since mech room is within bedroom
- Mechanical permit mec18-02559 for A/C is a mechanical aging permit and needs breaker changed out to a 25amp breaker
MEC19-02579 Final6/21/20196/24/20196/24/2019 10:48:02 AMAFAIL
Please have inspector call owner Matt at ###-#### before going out. Phone #: ###-#### Inspection requested via web by Carolyn Rudd
- need to seal line set penetration
- need to install co detector near bedrooms
MEC19-02555 Final6/21/20196/24/20196/24/2019 10:28:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Steve Hetherington
- furnace only co ok
MEC19-02573 Final6/21/20196/24/20196/24/2019 10:09:51 AMAFAIL
Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace ac coil co ok
- line set in attic needs supported
- condensate line needs to be min 3/4" and of approved materials. pump can be used to to gain grade before entering 3/4 material
MEC19-02160 Rough-in6/23/20196/24/20196/24/2019 9:52:49 AMAFAIL
Key is in light power box at back door Phone #: ###-#### Inspection requested via web by Aaron Toomey
- need stamped man J onsite
- 5lb flue pressure test fail gauge was at zero and PVC installed for vent needs to be solid core
- several locations need nail plates installed for line sets
- gas line needs 10 mill tape installed at penentration
- range vent needs backdraft damper
- 2nd systems looks like it needs finished
-line set in crawl needs supported
MEC19-02160 Pressure Test6/23/20196/24/20196/24/2019 9:48:06 AMAFAIL
Key is in light power box at back door Phone #: ###-#### Inspection requested via web by Aaron Toomey
- 5lb flue pressure test fail gauge was at zero
- tankless water heater vent needs to be ran in solid core PVC
- re test 20lb gas after 10 mill tape is installed at penentration
MEC19-02693 Final6/23/20196/24/20196/24/2019 8:33:09 AMAPASS
lock box / start at top left and zig zag down Phone #: ###-#### Inspection requested via web by Joseph Profitt
- final ok
MEC18-05482 Mec-Aging Inspection6/24/20196/24/20196/24/2019 8:16:37 AM DONE
Permit has not been active since being issued on 11/12/2018. If pellet stove has been installed schedule an inspection. Permit will expire if not active by next mechanical aging inspection and will have to be re issued once expired.
MEC18-05501 Mec-Aging Inspection6/24/20196/24/20196/24/2019 8:13:57 AM FAIL
Permit has not been active since a rough-in pass on 1/24/19. Schedule final inspection if work is finished. Permit will expire at next mechanical aging inspection and will have to be re issued once expired.
MEC18-05499 Mec-Aging Inspection6/24/20196/24/20196/24/2019 8:03:04 AM PASS
doc final ok
MEC18-05499 DOC - Permit Finaled6/24/20196/24/20196/24/2019 8:02:49 AMAPASS
doc final ok
MEC19-02609 Pressure Test6/19/20196/24/20196/24/2019 12:00:00 AMPCANC
Flue pressure test Phone #: ###-#### >> Inspection requested via web by Misty Merry