MEC19-02160
| Rough-in | 6/24/2019 | 6/24/2019 | 6/24/2019 3:56:40 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Aaron Toomey - CSST gas line needs approved manufactures nail plates installed - tankless water heater vent needs to be approved materials - need to see a 5lb flue pressure test
|
MEC19-02160
| Pressure Test | 6/24/2019 | 6/24/2019 | 6/24/2019 3:46:41 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Aaron Toomey - 20lb gas pressure test ok
|
MEC19-02277
| Final | 6/24/2019 | 6/24/2019 | 6/24/2019 3:04:50 PM | P | PASS |
|
|
Inspection requested via web by Margie Rowe - final ok
|
MEC19-02185
| Final | 6/24/2019 | 6/24/2019 | 6/24/2019 3:04:35 PM | P | PASS |
|
|
Inspection requested via web by Margie Rowe - final ok
|
MEC19-02449
| Final | 6/21/2019 | 6/24/2019 | 6/24/2019 2:50:59 PM | P | FAIL |
|
|
Please call Beth prior to heading out. ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby - line set insulation is too close to single wall water heater vent - need to see both upstairs and down stairs CO detectors installed near bedrooms
|
MEC19-01742
| Rough-in | 6/24/2019 | 6/24/2019 | 6/24/2019 2:35:01 PM | P | PASS |
|
|
Please call me a head of showing up incase I am able to meet you there. Approved manual j will be sitting on the furnace in the bigger room in the garage.
Thank you Phone #: ###-#### Inspection requested via web by Geff Blecha - R/I ok
|
MEC19-02657
| Final | 6/24/2019 | 6/24/2019 | 6/24/2019 2:01:37 PM | P | PASS |
|
|
Please call Ray about 15 minutes prior to inspection so he can get home from work. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace ac coil co ok
|
MEC19-02692
| Rough-in | 6/23/2019 | 6/24/2019 | 6/24/2019 1:43:47 PM | P | PART |
|
|
Please call James at ###-#### with any questions, thanks. Inspection requested via web by 4 Seasons - range vent ok - supply run in basment might be moved homeowner doesn't want to lower ceilings to cover duct work
|
MEC19-02618
| Final | 6/21/2019 | 6/24/2019 | 6/24/2019 11:23:18 AM | A | FAIL |
|
|
CONTACT DAN FOR QUESTIONS - ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - need to see electrical permit pulled for new ductless split
|
MEC19-02679
| Final | 6/21/2019 | 6/24/2019 | 6/24/2019 11:04:02 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Marisa Hone - need to witness 5lb flue pressure test - need to connect combustion air vent to furnace since mech room is within bedroom - Mechanical permit mec18-02559 for A/C is a mechanical aging permit and needs breaker changed out to a 25amp breaker
|
MEC19-02579
| Final | 6/21/2019 | 6/24/2019 | 6/24/2019 10:48:02 AM | A | FAIL |
|
|
Please have inspector call owner Matt at ###-#### before going out. Phone #: ###-#### Inspection requested via web by Carolyn Rudd - need to seal line set penetration - need to install co detector near bedrooms
|
MEC19-02555
| Final | 6/21/2019 | 6/24/2019 | 6/24/2019 10:28:41 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Steve Hetherington - furnace only co ok
|
MEC19-02573
| Final | 6/21/2019 | 6/24/2019 | 6/24/2019 10:09:51 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace ac coil co ok - line set in attic needs supported - condensate line needs to be min 3/4" and of approved materials. pump can be used to to gain grade before entering 3/4 material
|
MEC19-02160
| Rough-in | 6/23/2019 | 6/24/2019 | 6/24/2019 9:52:49 AM | A | FAIL |
|
|
Key is in light power box at back door Phone #: ###-#### Inspection requested via web by Aaron Toomey - need stamped man J onsite - 5lb flue pressure test fail gauge was at zero and PVC installed for vent needs to be solid core - several locations need nail plates installed for line sets - gas line needs 10 mill tape installed at penentration - range vent needs backdraft damper - 2nd systems looks like it needs finished -line set in crawl needs supported
|
MEC19-02160
| Pressure Test | 6/23/2019 | 6/24/2019 | 6/24/2019 9:48:06 AM | A | FAIL |
|
|
Key is in light power box at back door Phone #: ###-#### Inspection requested via web by Aaron Toomey - 5lb flue pressure test fail gauge was at zero - tankless water heater vent needs to be ran in solid core PVC - re test 20lb gas after 10 mill tape is installed at penentration
|
MEC19-02693
| Final | 6/23/2019 | 6/24/2019 | 6/24/2019 8:33:09 AM | A | PASS |
|
|
lock box / start at top left and zig zag down Phone #: ###-#### Inspection requested via web by Joseph Profitt - final ok
|
MEC18-05482
| Mec-Aging Inspection | 6/24/2019 | 6/24/2019 | 6/24/2019 8:16:37 AM | | DONE |
|
|
Permit has not been active since being issued on 11/12/2018. If pellet stove has been installed schedule an inspection. Permit will expire if not active by next mechanical aging inspection and will have to be re issued once expired.
|
MEC18-05501
| Mec-Aging Inspection | 6/24/2019 | 6/24/2019 | 6/24/2019 8:13:57 AM | | FAIL |
|
|
Permit has not been active since a rough-in pass on 1/24/19. Schedule final inspection if work is finished. Permit will expire at next mechanical aging inspection and will have to be re issued once expired.
|
MEC18-05499
| Mec-Aging Inspection | 6/24/2019 | 6/24/2019 | 6/24/2019 8:03:04 AM | | PASS |
|
|
doc final ok
|
MEC18-05499
| DOC - Permit Finaled | 6/24/2019 | 6/24/2019 | 6/24/2019 8:02:49 AM | A | PASS |
|
|
doc final ok
|
MEC19-02609
| Pressure Test | 6/19/2019 | 6/24/2019 | 6/24/2019 12:00:00 AM | P | CANC |
|
|
Flue pressure test Phone #: ###-#### >> Inspection requested via web by Misty Merry
|