Inspections for the day of: Monday, June 25, 2018.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-02271 Electrical Rough-In6/25/20186/25/20186/25/2018 1:51:08 PMPNR
I will call at noon to schedule a time to meet you at project Phone #: ###-#### Inspection requested via web by Jesse Simpson Need to remove panels from roof and reschedule final
ELE18-01858 Electrical Rough-In6/25/20186/25/20186/25/2018 1:50:30 PMPPASS
Wall cover Phone #: ###-#### Inspection requested via web by cris flores 1st floor 3 appartments only
ELE18-00545 Electrical Rough-In6/25/20186/25/20186/25/2018 1:32:38 PMPPASS
John will be there today. 2nd number Graham--###-#### Phone #: ###-#### original layout changed. Down kitchen ok to cover
ELE18-02356 Electrical Rough-In6/22/20186/25/20186/25/2018 1:11:28 PMPFAIL
Phone #: ###-#### Inspection requested via web by steve ragan Flat cable shall not be secured on edge, NM cable shall be secured within 8in of box and every4.5ft, cable sheething shall extend 1/4in inside box(hall vanity light) nail plates through out, Bath vanity circuit shall be 20amp and shall serve no others, recep shall be within 36in of vanity basin,Master bed switch box overfilled,14awg on 20amp circuit( Master bed fan and master vanity lights), Screw on boxes shall be listed for the purpose( Master vanity switch)
ELE18-02116 Electrical Rough-In6/25/20186/25/20186/25/2018 10:24:11 AMAPASS
Contact: Randy Shipley.... underground inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden Underground only ok to cover
ELE18-01724 Electrical Rough-In6/23/20186/25/20186/25/2018 10:23:42 AMAPASS
light pole bases Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Pole bases And underground only ok to cover
ELE18-00656 Final6/21/20186/25/20186/25/2018 9:59:47 AMAPASS
Danny is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen Final ok
ELE18-02210 Rough-In Permanent Service6/22/20186/25/20186/25/2018 8:59:11 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn rough in ok p/s u/g n ok
ELE18-02325 Electrical Rough-In6/21/20186/25/20186/25/2018 8:42:48 AMANR
Garage access code 1001e Phone #: ###-#### Inspection requested via web by Alan Lusk Called in by mistake
ELE18-02356 Electrical Rough-In6/22/20186/25/20186/22/2018 12:46:56 PMACANC
Phone #: ###-#### >> Inspection requested via web by steve ragan Inspection cancelled from web by: steve ragan