Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD20-00962 BLD-Wall cover6/25/20206/25/20206/25/2020 3:35:56 PMPPASS
screened - call for access // Sam Phone #: ###-####//ok to cover walls only//call for grid when ready//submit site plan for plan mod prior to final as it does not reflect the current conditions//
BLD20-01864 BLD-Footing6/24/20206/25/20206/25/2020 3:27:50 PMPPASS
This footing inspection can be done in the PM tomorrow. Nick will be doing the installation and his cell number is ###-####. Thanks! Phone #: ###-#### Inspection requested via web by rich prasch
BLD20-01136 BLD-Conference6/25/20206/25/20206/25/2020 3:09:29 PMPDONE
conference to discusse framing//ok to insulate//check framing corrections at the energy inspection//
BLD20-00751 BLD-Final6/24/20206/25/20206/25/2020 12:13:29 PMANR
owerns have been out of state in last 14 days // Greg Phone #: ###-####//need mechanical permit and final or remove requirement from scope of work//please meet onsite when re-scheduled to discuss project and photos//
BLD19-00532 BLD-Framing/Rough-in6/24/20206/25/20206/25/2020 11:47:28 AMAPART
Start checking trusses at 4th floor Phone #: ###-#### Inspection requested via web by Travis Blackburn//trusses were reviewed, one truss backward, one truss brace on wrong web, add nails to all hangers//provide clarificationf for hangers on 4 corners that spec to be installed upside down-and complete install//add H2.5s at corridor exterior bearing walls according to truss docs//
BLD20-01283 BLD-Wall Bracing6/24/20206/25/20206/25/2020 9:49:14 AMANR
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD20-01286 BLD-Wall Bracing6/24/20206/25/20206/25/2020 9:49:00 AMANR
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD20-01287 BLD-Wall Bracing6/24/20206/25/20206/25/2020 9:48:46 AMANR
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD20-01289 BLD-Wall Bracing6/24/20206/25/20206/25/2020 9:48:32 AMANR
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD20-00704 BLD-Framing/Rough-in6/24/20206/25/20206/25/2020 9:37:40 AMACANC
Phone #: ###-#### Inspection requested via web by Kelly Stover//need mechanical rough in completed prior to framing inspection//let Mark know//
BLD20-01835 BLD-Final6/24/20206/25/20206/25/2020 9:24:51 AMAFAIL
Permit is next to ac unit. Thank you! Phone #: ###-#### Inspection requested via web by Cassandra Hessing//CN issued--plans show 2 2x10 header for new window, window appears to b wider than what was existing, cannot verify header was installed//