BLD20-00962
| BLD-Wall cover | 6/25/2020 | 6/25/2020 | 6/25/2020 3:35:56 PM | P | PASS |
|
|
screened - call for access // Sam Phone #: ###-####//ok to cover walls only//call for grid when ready//submit site plan for plan mod prior to final as it does not reflect the current conditions//
|
BLD20-01864
| BLD-Footing | 6/24/2020 | 6/25/2020 | 6/25/2020 3:27:50 PM | P | PASS |
|
|
This footing inspection can be done in the PM tomorrow. Nick will be doing the installation and his cell number is ###-####. Thanks! Phone #: ###-#### Inspection requested via web by rich prasch
|
BLD20-01136
| BLD-Conference | 6/25/2020 | 6/25/2020 | 6/25/2020 3:09:29 PM | P | DONE |
|
|
conference to discusse framing//ok to insulate//check framing corrections at the energy inspection//
|
BLD20-00751
| BLD-Final | 6/24/2020 | 6/25/2020 | 6/25/2020 12:13:29 PM | A | NR |
|
|
owerns have been out of state in last 14 days // Greg Phone #: ###-####//need mechanical permit and final or remove requirement from scope of work//please meet onsite when re-scheduled to discuss project and photos//
|
BLD19-00532
| BLD-Framing/Rough-in | 6/24/2020 | 6/25/2020 | 6/25/2020 11:47:28 AM | A | PART |
|
|
Start checking trusses at 4th floor Phone #: ###-#### Inspection requested via web by Travis Blackburn//trusses were reviewed, one truss backward, one truss brace on wrong web, add nails to all hangers//provide clarificationf for hangers on 4 corners that spec to be installed upside down-and complete install//add H2.5s at corridor exterior bearing walls according to truss docs//
|
BLD20-01283
| BLD-Wall Bracing | 6/24/2020 | 6/25/2020 | 6/25/2020 9:49:14 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD20-01286
| BLD-Wall Bracing | 6/24/2020 | 6/25/2020 | 6/25/2020 9:49:00 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD20-01287
| BLD-Wall Bracing | 6/24/2020 | 6/25/2020 | 6/25/2020 9:48:46 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD20-01289
| BLD-Wall Bracing | 6/24/2020 | 6/25/2020 | 6/25/2020 9:48:32 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle
|
BLD20-00704
| BLD-Framing/Rough-in | 6/24/2020 | 6/25/2020 | 6/25/2020 9:37:40 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Kelly Stover//need mechanical rough in completed prior to framing inspection//let Mark know//
|
BLD20-01835
| BLD-Final | 6/24/2020 | 6/25/2020 | 6/25/2020 9:24:51 AM | A | FAIL |
|
|
Permit is next to ac unit. Thank you! Phone #: ###-#### Inspection requested via web by Cassandra Hessing//CN issued--plans show 2 2x10 header for new window, window appears to b wider than what was existing, cannot verify header was installed//
|