PLM00-02170
| Final | 6/23/2000 | 6/26/2000 | 6/26/2000 12:00:00 AM | A | PASS |
|
|
tom- ###-#### fn
|
PLM00-01719
| Plumbing Rough-in | 6/23/2000 | 6/26/2000 | 6/26/2000 12:00:00 AM | A | PASS |
|
|
reinspection kevin ###-####
|
PLM00-01991
| Plumbing Rough-in | 6/23/2000 | 6/26/2000 | 6/26/2000 12:00:00 AM | A | PASS |
|
|
called in by Jim Storey
|
PLM00-01672
| Groundwork | 6/23/2000 | 6/26/2000 | 6/26/2000 12:00:00 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 06/23/2000 at 15:39:21. Contact: ###-####. not complete 6/26/00 9:00:12 AM
|
PLM00-01111
| Other | 6/26/2000 | 6/26/2000 | 6/26/2000 12:00:00 AM | A | CANC |
|
|
Added by Inspector: 330 On 6/26/00 test
|
PLM00-01672
| Groundwork | 6/26/2000 | 6/26/2000 | 6/26/2000 12:00:00 AM | A | FAIL |
|
|
Scheduled by Inspector: 330 On 6/26/00 ann 4666661 for tomarrow 6/26/00 3:59:55 PM
|
PLM00-02170
| Plumbing Rough-in | 6/26/2000 | 6/26/2000 | 6/26/2000 12:00:00 AM | P | FAIL |
|
|
Added by Inspector: 330 On 6/26/00 additional piping not disclosed at prior ri prior inspection void, needs a pressure mixing valve at shower, listing for rubber tee at lav, vent washer and service sink wastes, if other than residential occ provide premis and thermol expantion protection and water service upgrade
|
PLM00-01672
| Groundwork | 6/26/2000 | 6/26/2000 | 6/26/2000 12:00:00 AM | P | FAIL |
|
|
###-#### Ann for tomarrow 6/26/00 4:00:10 PM
|