Inspections for the day of: Monday, June 26, 2006.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS06-00066 MIS-Aging Inspection6/26/20066/26/20066/27/2006 8:02:49 AM NR
BLD04-03025 BLD-Framing/Rough-in6/26/20066/26/20066/26/2006 3:59:04 PMPFAIL
Scheduled by a contractor via Hello! on 6/26/2006 at 7:52:30 AM. Contact: ###-####. 2nd floor,north wing. Needs to supply an approved fix and fix all fllor joist that have been cut or notched. Needs to install straps on top plates and repair studs that have been cut. Also needs to repair shaft at northend rooms. ok to insul. walls.
BLD06-00580 BLD-Other6/23/20066/26/20066/26/2006 2:30:51 PMPPART
Scheduled by a contractor via Hello! on 6/23/2006 at 10:15:42 AM. Contact: ###-####.exterior shear nailing.
BLD05-02018 BLD-Final6/23/20066/26/20066/26/2006 2:02:43 PMPPART
Scheduled by a contractor via Hello! on 6/23/2006 at 1:18:26 PM. Contact: ###-####. ok for temp occ. Need final aff. letter from special insp. firm. Also noted that handrail for stairway to mech. does not have proper clearance at two points from guard and does not return properly at top. Contractor noted that access to these stairs is not needed and wiil be closed off so that no access is granted until it is repaired. these stairs not part of exut system.
MIS06-00083 MIS-Aging Inspection6/26/20066/26/20066/26/2006 1:07:56 PM PASS
owner of bldg has recieved the c/n notice and has hired an architect and has spoken to plan review to correct non conformance. wip.
MIS06-00067 MIS-Aging Inspection6/26/20066/26/20066/26/2006 11:14:37 AM DONE
MIS06-00067 DOC - Permit Finaled6/26/20066/26/20066/26/2006 11:14:28 AMPPASS
no evidence of construction, no dumpsteers or construction debris were noted.
BLD06-01730 BLD-Footing6/23/20066/26/20066/26/2006 10:49:03 AMAPART
terry; Phone #: ###-#### Internet Inspection Request from: Rita DeYoung. roots removed and bottom of footing almost clean. wip.
BLD06-00756 BLD-Conference6/23/20066/26/20066/26/2006 10:13:52 AMADONE
rob; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
BLD06-00016 BLD-Energy code compliance6/25/20066/26/20066/26/2006 9:47:45 AMAPASS
Scheduled by a contractor via Hello! on 6/25/2006 at 10:55:36 AM. Contact: ###-####. ok to cover. Hvac shaft has been sealed.
BLD06-00785 BLD-Final6/22/20066/26/20066/26/2006 9:19:00 AMANR
If locked, one of two keys above door will provide entry. Other key is for restroom down the hall; Phone #: ###-#### Internet Inspection Request from: Gary Band. Needs life/safety final first.