MIS17-00203
| ELE-Conference | 6/26/2017 | 6/26/2017 | 6/26/2017 2:39:51 PM | P | DONE |
|
|
Service feeders on roof, No one answered the door will keep trying Overhead feeders are on metal roof, discussed with homeowners son about the dangers of this service installation and gave a 30 notice too have a plan in place to have the issues resolved. Within a hour of given notice Enterprise Electric called about replacing service and was great owners son jumped on right away. Service change will happen shortly.
|
ELE17-01966
| Final | 6/26/2017 | 6/26/2017 | 6/26/2017 1:36:03 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Barbara Szurgot Final ok
|
ELE17-01755
| Permanent Service | 6/26/2017 | 6/26/2017 | 6/26/2017 1:13:39 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tom Jenkins p/s o/h rec ok
|
ELE17-01963
| Permanent Service | 6/26/2017 | 6/26/2017 | 6/26/2017 12:51:27 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bryan McLaughlin p/s o/h rec ok
|
ELE17-02001
| Permanent Service | 6/23/2017 | 6/26/2017 | 6/26/2017 12:29:23 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Atkins Service ok to re-energize and will plan on service change this week to bring all to code p/s o/h rec ok
|
ELE16-03597
| Final | 6/26/2017 | 6/26/2017 | 6/26/2017 12:13:02 PM | P | FAIL |
|
|
We Are Ready For A,Final On This Job Lockbox On Front Door Code Is 4290..Please Call With Any Questions Or Concerns Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett 210.8 All receptacles located in comm kitchens shall have GFCI protection Remove existing wiring light out back with wires hanging
|
ELE13-01035
| ELE-Aging Inspection | 6/26/2017 | 6/26/2017 | 6/26/2017 9:46:21 AM | | PASS |
|
|
Called and talked with him and he will look into finalling it out
|
ELE12-00736
| ELE-Aging Inspection | 6/26/2017 | 6/26/2017 | 6/26/2017 9:39:43 AM | | DONE |
|
|
Called and left a message
|
ELE12-01307
| ELE-Aging Inspection | 6/26/2017 | 6/26/2017 | 6/26/2017 9:36:42 AM | | PASS |
|
|
Finalled this permit out
|
ELE12-01307
| Final | 6/26/2017 | 6/26/2017 | 6/26/2017 9:36:19 AM | P | PASS |
|
|
Final for underground conduit ok
|
ELE13-01998
| ELE-Aging Inspection | 6/26/2017 | 6/26/2017 | 6/26/2017 9:33:48 AM | | FAIL |
|
|
Called and left message
|
ELE17-01912
| Electrical Rough-In | 6/26/2017 | 6/26/2017 | 6/26/2017 9:23:55 AM | P | PASS |
|
|
This Rough In Is Ready The Only Thing I Have Left Is I Ordered A,Piece Of Sheet Metal For Covering The Old Panel Cover..But It Will Be On There On Trim..The Lock Box Is On The Front Door And The Code Is 195 Thanks So Much And Please Call With Any Questions ###-#### Phone #: ###-#### Inspection requested via web by jason shifflett Kitchen,hall bath,laundry and sdding cans in main and off kitchen living rooms only ok cover
|
MIS17-00203
| ELE-Conference | 6/23/2017 | 6/26/2017 | 6/26/2017 9:08:20 AM | A | CANC |
|
|
Idaho Power conplaint- Overhead service conductors laying on roof. Fire hazard No one answered door will keep trying
|
ELE17-01946
| Final | 6/26/2017 | 6/26/2017 | 6/26/2017 8:32:29 AM | P | PASS |
|
|
new 200 amp service. out door meter, indoor panel Phone #: ###-#### Inspection requested via web by Douglas Hackney Final for service change ok
|
ELE17-01946
| Permanent Service | 6/26/2017 | 6/26/2017 | 6/26/2017 8:32:02 AM | A | PASS |
|
|
new 200 amp service. out door meter, indoor panel Phone #: ###-#### Inspection requested via web by Douglas Hackney Idaho power already energized service p/s o/h rec ok
|