PLM17-02346
| Final | 6/26/2017 | 6/26/2017 | 6/26/2017 3:33:53 PM | P | PASS |
|
|
Micheal Phone #: ###-####
|
PLM17-02334
| Plumbing Rough-in | 6/23/2017 | 6/26/2017 | 6/26/2017 3:14:24 PM | P | FAIL |
|
|
Inspection requested via web by Brian Johansen-DWV test fail both sides. Kitchen trap arm right side is backgraded. 1 1/2 san tee right side above laundry on vevt installed in wrong direction.
|
PLM17-02354
| Final | 6/26/2017 | 6/26/2017 | 6/26/2017 2:41:42 PM | P | PASS |
|
|
Please call customer 30 min prior to arriving. Please arrive after 1 pm Phone #: ###-#### Inspection requested via web by Andrea Grigsby
|
PLM17-01034
| Plumbing Rough-in | 6/23/2017 | 6/26/2017 | 6/26/2017 2:11:38 PM | P | PASS |
|
|
Inspection requested via web by Brian Johansen
|
PLM17-00614
| Storm Drains | 6/23/2017 | 6/26/2017 | 6/26/2017 1:47:48 PM | P | PART |
|
|
South-East corner of building 51. Continuation of 12in storm drain line heading North. Installing stubs for 4in roof leader connections to 12in main line. Phone #: ###-#### Inspection requested via web by Craig Fischer-Section complete ok to cover, still needs tested.
|
MEC17-01618
| Rough-in | 6/26/2017 | 6/26/2017 | 6/26/2017 1:46:59 PM | P | PASS |
|
|
mechanical fireplace rough in inspection Phone #: ###-#### Inspection requested via web by Dan Otero
|
PLM17-02347
| Plumbing Rough-in | 6/26/2017 | 6/26/2017 | 6/26/2017 1:01:32 PM | P | FAIL |
|
|
DWV test fail & need access to tie-in parking area.
|
PLM17-02347
| Final | 6/26/2017 | 6/26/2017 | 6/26/2017 12:59:13 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by PATTY KIRK
|
PLM17-00614
| Water and/or Sewer | 6/23/2017 | 6/26/2017 | 6/26/2017 11:25:58 AM | A | NR |
|
|
West side of building 51. Continuation of 8in potable water heading South. Phone #: ###-#### Inspection requested via web by Craig Fischer
|
PLM17-00614
| Storm Drains | 6/23/2017 | 6/26/2017 | 6/26/2017 11:25:23 AM | A | NR |
|
|
North-West corner building 51. Connection of 12in Storm Drain line from building 50 into existing manhole, tie-in 8in storm drain line from building 51 into 12in line. Phone #: ###-#### Inspection requested via web by Craig Fischer
|
MEC17-01523
| Conference | 6/23/2017 | 6/26/2017 | 6/26/2017 10:12:43 AM | A | DONE |
|
|
Need a conference with the inspector Monday A.M. With Rob # ###-#### if unable to reach Rob Call Karl at ###-#### This is for Ranch market Coffee thank you Phone #: ###-#### Inspection requested via web by Karl Hestekin-Conferance on grease duct.
|
PLM17-01367
| Final | 6/23/2017 | 6/26/2017 | 6/26/2017 10:11:50 AM | A | PASS |
|
|
Garage code 1001. Phone #: ###-#### Inspection requested via web by David Stephenson
|
PLM17-00798
| Plumbing Rough-in | 6/26/2017 | 6/26/2017 | 6/26/2017 9:18:17 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Matthew Hansen
|
PLM17-02344
| Water and/or Sewer | 6/26/2017 | 6/26/2017 | 6/26/2017 8:39:16 AM | A | PASS |
|
|
Ready to go Phone #: ###-#### Inspection requested via web by keith braun
|
PLM17-02344
| DOC - Permit Finaled | 6/26/2017 | 6/26/2017 | 6/26/2017 8:39:04 AM | P | PASS |
|
|
|
PLM17-02331
| Final | 6/23/2017 | 6/26/2017 | 6/26/2017 8:24:05 AM | A | PASS |
|
|
Homeowner requests early morning inspection, contact Mike @ ###-#### or Kevin (QHC) @ Phone #: ###-#### Inspection requested via web by Kevin Pratley
|
PLM17-02121
| Plumbing Rough-in | 6/23/2017 | 6/26/2017 | 6/26/2017 7:52:34 AM | P | CANC |
|
|
JOB # 19166. Phone #: ###-#### >> Inspection requested via web by Ann Marie Reyes Inspection cancelled from web by: Ann Marie Reyes
|
PLM16-03201
| PLM-Aging Inspection | 6/26/2017 | 6/26/2017 | 6/26/2017 6:02:02 AM | | PART |
|
|
No calls
|
PLM17-01858
| Final | 6/23/2017 | 6/26/2017 | 6/23/2017 4:37:54 PM | A | CANC |
|
|
Call Thomas for access or Abel ###-#### Current plans are on site per Abel Phone #: ###-#### >> Inspection requested via web by Nick Drake Inspection cancelled from web by: Nick Drake
|