Inspections for the day of: Wednesday, June 26, 2019.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-01202 Final6/26/20196/26/20196/26/2019 2:52:00 PMPPASS
Call for access information thank you Phone #: ###-#### Inspection requested via web by kim grundhauser final ok
ELE19-01966 Final6/26/20196/26/20196/26/2019 1:59:57 PMPPASS
Pls contact Bryce (Foreman) @ ###-#### or George (Electrician) @ ###-#### one hr prior or if you have any questions. Thank you. Inspection requested via web by Rob Maes Final ok
ELE19-02334 Electrical Rough-In6/26/20196/26/20196/26/2019 1:15:45 PMPPASS
Underground and bonding for swimming pool Phone #: ###-#### Inspection requested via web by Lars Johnson UG and corner bond ok
ELE19-02239 Rough-In Permanent Service6/24/20196/26/20196/26/2019 1:14:35 PMPCANC
Please call Mitch Whited at ###-#### 30 minutes prior. Phone #: ###-#### Inspection requested via web by Mitch Whited
ELE18-04573 Electrical Rough-In6/25/20196/26/20196/26/2019 1:14:09 PMPPASS
Equipotential and potting
Phone #: ###-#### Inspection requested via web by Kevin Koomler eq bond and potting ok
ELE19-02208 Rough-In Permanent Service6/25/20196/26/20196/26/2019 11:12:57 AMACANC
Phone #: ###-#### Inspection requested via web by TOM BICANDI
ELE19-02208 Electrical Rough-In6/26/20196/26/20196/26/2019 11:12:47 AMPPASS
Phone #: ###-#### Inspection requested via web by TOM BICANDI Garage converted to 2 beds, bath, Laundry rm, and kitchen, dining. Corrections made rough in ok
ELE19-02158 Electrical Rough-In6/25/20196/26/20196/26/2019 10:54:36 AMAPASS
Please call the number above before heading to the jobsite. Thank you! Phone #: ###-#### Inspection requested via web by BRS Permitting Listing only ok
ELE19-01348 Final6/25/20196/26/20196/26/2019 10:47:35 AMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
ELE19-01347 Final6/25/20196/26/20196/26/2019 10:39:39 AMAFAIL
Garage code 1957 Phone #: ###-#### Inspection requested via web by Therrin Robertson
Strap riser
Trim recep in office closet
Missing plates in mason
ELE19-02369 Final6/25/20196/26/20196/26/2019 10:17:42 AMAFAIL
Please call our office before heading that way. Call Brodie with any questions, customer will be on site. Phone #: ###-#### Inspection requested via web by William Salts MC shall be connected with listed connector.(Connection to indoor wall unit made by others.) BCC Section 9-05-32. No violation shall be retained.
ELE19-01826 Electrical Rough-In6/24/20196/26/20196/26/2019 9:14:30 AMAPASS
Lance Phone #: ###-#### Equipment rough in ok All motor disc. checked. MCC feeds most loads. All motor Over current provided in MCC. Permit ok to final after parcel hold lifted.