MEC19-02752
| Pressure Test | 6/25/2019 | 6/26/2019 | 6/26/2019 4:01:42 PM | P | PASS |
|
|
Please schedule in the afternoon - installing new equipment in the morning and call Carl (###-####) 30 minutes prior to showing up. Please do Pressure Test and Final Inspection at same time. If unable to reach Carl please call Michele @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Michele Johnson - 5lb flue pressure test ok - call in final when ready - existing condensate line was tapped into drain in basement and cant be ran outside due to freezing temp in winter. contractor onsite said most likely a plumber would take care of condensate line. will need to see plumbing permit pulled for final
|
MEC19-00819
| Final | 6/26/2019 | 6/26/2019 | 6/26/2019 3:30:34 PM | P | PASS |
|
|
RUSSELL IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER - final ok - no occ card onsite to sign
|
MEC19-00819
| Card not on site to sign | 6/26/2019 | 6/26/2019 | 6/26/2019 3:30:20 PM | P | PASS |
|
|
RUSSELL IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER - no card onsite pass
|
MEC19-02711
| Final | 6/24/2019 | 6/26/2019 | 6/26/2019 2:50:18 PM | P | PASS |
|
|
installer Nick ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - furnace ac coil co ok
|
MEC19-01824
| Final | 6/25/2019 | 6/26/2019 | 6/26/2019 2:03:38 PM | P | NR |
|
|
Please call Kyle to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg
|
MEC19-02742
| Final | 6/25/2019 | 6/26/2019 | 6/26/2019 1:42:23 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Marisa Hone - furnace ac coil co ok
|
MEC19-01212
| Rough-in | 6/25/2019 | 6/26/2019 | 6/26/2019 11:30:24 AM | A | PART |
|
|
partial inspection on Heat Water System Josh ###-#### Phone #: ###-#### Inspection requested via web by RM Mechanical - area A 100lb hydronics pressure test ok
|
MEC19-01845
| Rough-in | 6/25/2019 | 6/26/2019 | 6/26/2019 10:31:38 AM | A | FAIL |
|
|
Code 2390 Phone #: ###-#### Inspection requested via web by Ashley Shoecraft - need to see non combustibles installed on top and sides of fireplaces - bedroom fireplace has combustibles touching vent - need to see gas lines stubbed into fireplaces
|
MEC19-01700
| Rough-in | 6/25/2019 | 6/26/2019 | 6/26/2019 9:54:40 AM | A | PART |
|
|
PART Phone #: ###-#### Inspection requested via web by Oleg Chervak - east side bld K duct seal and R/I ok
|
MEC19-01022
| Final | 6/25/2019 | 6/26/2019 | 6/26/2019 9:23:54 AM | A | CANC |
|
|
|
MEC19-01022
| Rough-in | 6/26/2019 | 6/26/2019 | 6/26/2019 9:23:18 AM | A | PASS |
|
|
partial final for Units:135, 136, 233, 234, 235, and 236. Phone #: ###-#### Inspection requested via web by Nicholas Paige - 135,136,233,234,235,236 R/I ok call final when units are finished
|
MEC19-02272
| Pressure Test | 6/25/2019 | 6/26/2019 | 6/26/2019 8:55:18 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Nicholas Paige - high pressure test needs to be on 100lb gauge - gas piping penetration needs protective coating
|
MEC18-03260
| Mec-Aging Inspection | 6/26/2019 | 6/26/2019 | 6/26/2019 8:21:40 AM | | PASS |
|
|
Doc Expire ok permit was not active
|
MEC18-03260
| DOC - Permit Expired | 6/26/2019 | 6/26/2019 | 6/26/2019 8:20:31 AM | A | PASS |
|
|
permit not active doc expire ok
|