Inspections for the day of: Friday, June 26, 2020.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD20-00673 BLD-Footing6/25/20206/26/20206/26/2020 4:05:31 PMPDEFR
Shane - Pour time at noon Phone #: ###-####. Ok to place concrete pending special inspection.
BLD19-04563 BLD-Final6/26/20206/26/20206/26/2020 3:42:55 PMPDONE
Phone #: ###-#### Inspection requested via web by James Hibbard
BLD19-04563 DOC - Permit Finaled6/26/20206/26/20206/26/2020 3:42:54 PMPPASS
BLD20-00941 BLD-Conference6/26/20206/26/20206/26/2020 2:49:46 PMPDONE
Needs to provide approved mix designs for concrete. Also needs to upload plan mod for udated structural sheet S1.11 showing new grade beam layout. Contractor want to place concrete Monday morning June 29th. Noted to contractor (Visser) that they will be placing concrete at their own risk and any non conformances will be repaired or replaced.
BLD20-01856 BLD-Final6/25/20206/26/20206/26/2020 2:45:33 PMPDONE
Onsite contact: Lynsie Hart ###-#### Phone #: ###-#### Inspection requested via web by BRS Permitting
BLD20-01856 DOC - Permit Finaled6/26/20206/26/20206/26/2020 2:45:32 PMPPASS
BLD20-00660 BLD-Final6/25/20206/26/20206/26/2020 2:01:03 PMPPART
AN Phone #: ###-####. Ok for temp occ. Needs to submit plan mod for new bar area that has been constructed in place of the self serve beverage area.
BLD19-03470 BLD-Final6/25/20206/26/20206/26/2020 1:25:27 PMPPASS
Call before arriving Ed Phone #: ###-####. The tempered glazing has been installed in the overhead door. Ok for perm occ.
BLD19-00441 BLD-Final6/25/20206/26/20206/26/2020 12:39:44 PMPFAIL
Please give me a call 30 minutes ahead so that I can meet you on site for a walk through. Thank you. Jay Phone #: ###-#### Inspection requested via web by Jay Bedsole//CN issued//handrails need added and adjusted to meet code at stairway inside home//window near shower needs safety glazed//smok and smoke/co combos need to be interconnected--wireless interconnection allowed by code//adjust spring hinges on garage door//egress window needed in bedroom converted from den per plans and description//other window sizes were not changed//
BLD20-01465 BLD-Foundation6/25/20206/26/20206/26/2020 11:44:06 AMAFAIL
wall.. call to meet // Scott ........ Screened Phone #: ###-####. Needs to locate property line or have reduce setback approved by zoning and show soffit protection on plans
BLD20-00286 BLD-Energy code compliance6/25/20206/26/20206/26/2020 11:40:37 AMAFAIL
Phone #: 20848455 >> Inspection requested via mobile web by Ben covert. Tall walls(living room) were batt insulation has used shall be encapsulated on all six sides. Correction notice posted.
BLD20-01826 BLD-Footing6/25/20206/26/20206/26/2020 10:43:51 AMAFAIL
Footing permit can be done at anytime tomorrow. Subgrade is completed and has been emailed to Melissa and Jason. Thanks! Phone #: ###-#### Inspection requested via web by rich prasch. Footings are not min. 32X32x32 as per the enfineering.
BLD19-03942 BLD-Final6/25/20206/26/20206/26/2020 10:16:48 AMANR
screened // Jeff Phone #: ###-####. Needs public works and zoning final?
BLD20-00660 FIRE-Final Inspection6/25/20206/26/20206/26/2020 9:32:42 AMAPASS
AN Phone #: ###-####. City approved plans have been provided. All exit and emergency lighting have been repaired.
BLD20-01600 BLD-Framing/Rough-in6/25/20206/26/20206/26/2020 9:04:41 AMAPASS
Jay Phone #: ###-####
BLD20-01995 BLD-Final6/25/20206/26/20206/26/2020 8:50:36 AMADONE
Please contact Eric @ ###-#### if you have any questions. Thank you, Rob Inspection requested via web by Rob Maes
BLD20-01995 DOC - Permit Finaled6/26/20206/26/20206/26/2020 8:50:26 AMPPASS
BLD20-00468 BLD-Final6/25/20206/26/20206/26/2020 8:41:28 AMAPART
Temporary C of O until plumbing issues are addressed. Phone #: ###-#### Inspection requested via web by Brady Hutchins. Ok for temp occ. Needs to correct plumbing issues. Will be ok for per occ. once plumbing signs perm.
BLD20-00209 BLD-Footing6/25/20206/26/20206/26/2020 8:40:18 AMAPART
AM inspection would like to place concrete at 10:30 am Phone #: ###-#### Inspection requested via web by John Saucerman. ADA ramp, interior column pad footings and exterior stairs. Ok pending special inspection.