FIR08-00018
| INSP-Sprinkler Rough-in | 6/26/2008 | 6/27/2008 | 6/30/2008 11:44:20 AM | A | DEFR |
|
|
Rough-In Inspection Phone #: ###-#### x1234 Internet Inspection Request from: Alicia Pauley
|
BLD08-00919
| FIRE-Final Inspection | 6/27/2008 | 6/27/2008 | 6/27/2008 4:13:10 PM | P | PART |
|
|
Need to add exit signage as discussed, will verify and test EM lighting at next scheduled visit, remainder of fire life safety is acceptable.
|
FIR08-00392
| INSP-Final Inspection | 6/27/2008 | 6/27/2008 | 6/27/2008 4:11:41 PM | P | PASS |
|
|
C/N items verified for compliance, fire sprinkler permit finaled.
|
BLD08-01003
| FIRE-Final Inspection | 6/26/2008 | 6/27/2008 | 6/27/2008 3:42:35 PM | A | PART |
|
|
Fire life safety is acceptable for the portion of remodeled area west of the demising wall, noted fire extingushers are due annual certification next month (7/08), project final pending completion of permit work at the curently occupied Children's Store.
|
BLD08-00512
| FIRE-Final Inspection | 6/27/2008 | 6/27/2008 | 6/27/2008 3:06:58 PM | P | PART |
|
|
See city approved plans for area marked in red for tempory occupancy. As per Mark Senteno.Door hardware, exit signs, egress lights and fire extinguishers are approved.One hour rated fire wall shall be completed and approved by Jim Sly before area occupancy. KR
|
FIR08-00450
| INSP-Final Inspection | 6/26/2008 | 6/27/2008 | 6/27/2008 2:34:25 PM | A | PART |
|
|
Noted one missing a/v and one overspaced notification device at a hallway and conference room on the west side of the 5th floor area. Locations on approved plans are acceptable- field install needs to match per annotations. NOTE: notification at suite 501 passed inspection, suite 500 pending field adjustments.
|
FIR07-01031
| INSP-Sprinkler Rough-in | 6/27/2008 | 6/27/2008 | 6/27/2008 2:25:27 PM | P | PART |
|
|
See red line areas on plans for areas ok to cover.KR
|
FIR08-00385
| INSP-Sprinkler Rough-in | 6/26/2008 | 6/27/2008 | 6/27/2008 2:24:04 PM | A | FAIL |
|
|
Pendent heads at the room marked "file storage" are overspaced-need to install per approved plan.
|
BLD07-03288
| FIRE-Final Inspection | 6/27/2008 | 6/27/2008 | 6/27/2008 2:08:11 PM | P | FAIL |
|
|
Need to remove exit light from rear door, not a public way exit. Shall install exit sign and egress lighting at new door. KR
|
BLD08-00870
| FIRE-Final Inspection | 6/27/2008 | 6/27/2008 | 6/27/2008 1:46:25 PM | P | FAIL |
|
|
A sprinkler permit was pulled to relocate heads FIR08-00272 and has been passed. A smoke detector was relocate without a permit by Allied General. They will be pulling a quick permit for testing before we can final life safety on building permit. KR
|
BLD08-01197
| FIRE-Final Inspection | 6/24/2008 | 6/27/2008 | 6/27/2008 12:58:04 PM | P | PASS |
|
|
Fire life safety completed. KR
|
BLD08-01088
| FIRE-Final Inspection | 6/26/2008 | 6/27/2008 | 6/27/2008 12:39:32 PM | A | PASS |
|
|
Shell only permit. Fire extinguisher will be address on TI permit. KR
|
BLD08-00080
| FIRE-Final Inspection | 6/26/2008 | 6/27/2008 | 6/27/2008 12:24:48 PM | A | PASS |
|
|
Life safety inspection passed, tactile signage at the area of refuge to be installed when delivered per contractor, public phone line to be installed today-can be verified at next visit for the adjacent project.
|
FIR08-00158
| INSP-Sprinkler Rough-in | 6/26/2008 | 6/27/2008 | 6/27/2008 12:23:08 PM | A | PART |
|
|
Ok to cover 9' out from building. See city approved plans for details. KR
|
BLD07-01932
| FIRE-Final Inspection | 6/27/2008 | 6/27/2008 | 6/27/2008 12:06:30 PM | A | PART |
|
|
Building fire life safety approval pending project related fire alarm permit final. EM lights and exit signs tested okay with the exception of one light at the 2nd floor to be repaired today per the electrician, some doors at the 1st floor are not yet installed, need to remove the manual thumbturn at one exit door 1st floor SW side.
|
FIR08-00047
| INSP-Final Inspection | 6/26/2008 | 6/27/2008 | 6/27/2008 11:56:54 AM | A | PART |
|
|
Final pending completion of elevator controls to enable testing and functionality of recall, shunt trip, fire hat, etc. Remainder of items listed on the correction notice are finished, as-builts accepted. NFPA 72 record of completion forms have not been signed pending elevator testing.
|
FIR08-00394
| INSP-Final Inspection | 6/26/2008 | 6/27/2008 | 6/27/2008 11:06:53 AM | P | CANC |
|
|
Inspection to be rescheduled.
|
FIR07-00672
| INSP-Final Inspection | 6/26/2008 | 6/27/2008 | 6/27/2008 10:52:10 AM | A | PASS |
|
|
All fire alarm testing completed. KR
|
FIR07-00839
| INSP-Final Inspection | 6/26/2008 | 6/27/2008 | 6/27/2008 10:50:30 AM | A | FAIL |
|
|
Exhaust fan shut down during test, fan shall remain on when system is tripped. Electrical power under hood did not shut off.All power under shall shut down. KR
|
BLD06-03277
| FIRE-Final Inspection | 6/26/2008 | 6/27/2008 | 6/27/2008 10:37:36 AM | A | FAIL |
|
|
All testing completed. Could not pass until kitchen hood system permit is finaled. KR
|
FIR07-00874
| INSP-Sprinkler Rough-in | 6/26/2008 | 6/27/2008 | 6/27/2008 10:03:30 AM | P | CANC |
|
|
james Note: cover up Phone #: ###-#### Inspection cancelled from web by: Alexandra Rahn
|
BLD08-00871
| BLD-Final | 6/25/2008 | 6/27/2008 | 6/26/2008 11:02:44 AM | A | PASS |
|
|
Fire life safety finaled.
|