Inspections for the day of: Friday, June 27, 2014.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-01683 Electrical Rough-In6/27/20146/27/20146/27/2014 2:20:26 PMPPASS
Laryy Phone #: ###-#### Rough in ok cover
ELE14-01550 Electrical Rough-In6/27/20146/27/20146/27/2014 2:00:44 PMPPASS
lighting retrofit rough in Phone #: ###-#### >> Inspection requested via web by Tim Dunlop UL listing confirmed on all outdoor fixtures. Rough in ok
ELE14-01683 Permanent Service6/27/20146/27/20146/27/2014 1:58:56 PMPPASS
Laryy Phone #: ###-#### p/s o/h rec ok
MIS14-00147 ELE-Conference6/26/20146/27/20146/27/2014 1:23:04 PMADONE
Please call Pam with feedback Phone #: ###-#### Spoke with home owner he denied having done or doing any under ground electrical work. No evidence visible from street or driveway.
ELE14-01095 Final6/26/20146/27/20146/27/2014 12:58:47 PMAFAIL
Phone #: ###-#### >> Inspection requested via web by Stacie Tasker 210.12- All 15 and 20 amp 120 volt outlets shall have AFCI protection.
210.52(C)(1)- A receptical outlet shall be located with in 24" of left side of range.
210.63- A 120 volt 15 or 20 amp receptical outlet shall be located with in 25' of AC unit accessible from outside.
406.11- All areas specified in 210.52 all 15 and 20 amp 120 volt receptical outlet shall be tamper resistant type.
ELE14-01711 Conference6/26/20146/27/20146/27/2014 10:29:09 AMADONE
Erik Phone #: ###-#### Discussed code requirements and inspection process for wiring of detatached garage
ELE14-01387 Final6/27/20146/27/20146/27/2014 10:26:09 AMPPASS
Home owner has secured permit for interior wiring of detached garage. Final ok
ELE13-03546 Electrical Rough-In6/26/20146/27/20146/27/2014 9:58:30 AMAPASS
under ground inspection please-terrie Phone #: ###-#### Under ground for fiber and sign rough in ok cover
ELE14-01676 Electrical Rough-In6/26/20146/27/20146/27/2014 9:38:33 AMAPASS
enter through rear door to stairs to basement. (2) rooms at rear plus (1) new bathroom Phone #: ###-#### >> Inspection requested via web by Kevin Thruston Rough in ok cover
ELE13-00015 Permanent Service6/27/20146/27/20146/27/2014 9:20:31 AMAPASS
hi Rock it''s Rex I have old panel temporarily fed for swap over. please call if you have any questions! thanks Phone #: ###-#### >> Inspection requested via web by Rex Boyles p/s o/h rec ok
ELE14-01293 Final6/26/20146/27/20146/27/2014 9:01:13 AMAPASS
final on wiring of shed, any questions call Andy @ ###-#### Phone #: ###-#### >> Inspection requested via web by Andy Rose Final ok
ELE14-01319 Final6/26/20146/27/20146/27/2014 8:42:41 AMAPASS
Please call Lynn Proctor at ###-#### if you have any questions, comments or concerns. Phone #: ###-#### >> Inspection requested via web by Lynn Proctor Final ok