Inspections for the day of: Tuesday, June 27, 2017.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-01815 Final6/27/20176/27/20176/27/2017 1:40:58 PMPPASS
Chad VanOrden is contact at ###-####. thank you Phone #: ###-#### Inspection requested via web by Debby Pierce...

ok to final
ELE17-01993 Permanent Service6/27/20176/27/20176/27/2017 1:01:03 PMPPASS
Kelley ###-####...

p/s o/h rec ok
ELE13-02178 ELE-Aging Inspection6/27/20176/27/20176/27/2017 12:45:08 PM FAIL
contractor needs to obtain access and schedule inspection
ELE12-01841 ELE-Aging Inspection6/27/20176/27/20176/27/2017 12:44:09 PM DONE
waiting on contractor to schedule to close
ELE17-00416 Electrical Rough-In6/27/20176/27/20176/27/2017 12:42:32 PMPPASS
underground
contact is John Phone #: ###-#### Inspection requested via web by Lori Stout...

underground for parking lot lights...ok to cover
ELE17-01904 Electrical Rough-In6/26/20176/27/20176/27/2017 12:17:21 PMPPASS
We are requesting a wall rough-in inspection for tomorrow June 27th in the afternoon. Our contact is Dave Baugh @ ###-####. Thank you,
Phone #: ###-#### Inspection requested via web by Clint Tate...

dividing wall...highlighted on print..ok to cover
ELE17-01565 Final6/26/20176/27/20176/27/2017 12:05:45 PMPPASS
Corbin ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg...

corrections made....ok to final
ELE16-01758 Final6/27/20176/27/20176/27/2017 11:44:33 AMPFAIL
Phone #: ###-#### Inspection requested via web by cris flores...

1) A/C OCPD is to large..needs sized to nameplate
2) sub panel needs completely labelled
3) rated boxes for exterior need installed on m/c subs..westside of building
4) broken bell box with exposed wires needs fixed...southside of building
5) strap on riser pipe at service...requested on previous inspection
6) second rod at service needs completely installed
ELE17-02033 Rough-In Permanent Service6/27/20176/27/20176/27/2017 10:48:19 AMPPASS
Phone #: ###-#### Inspection requested via web by cal crosby...

rough ok to cover
p/s u/g n ok
MIS17-00197 ELE-Conference6/20/20176/27/20176/27/2017 10:11:10 AMAFAIL
recheck ....

no one home and no work being done at this time...no electrical permit has been pulled yet on work previously done
ELE16-02852 Final6/26/20176/27/20176/27/2017 9:56:06 AMAPASS
Gram Phone #: ###-####....

ok to final
ELE17-01036 Final6/26/20176/27/20176/27/2017 9:35:46 AMAPASS
Phone #: ###-#### Inspection requested via web by Jim Williams...

ok to final
ELE17-01280 Final6/27/20176/27/20176/27/2017 9:10:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn...

ok to final
ELE17-01840 Rough-In Permanent Service6/26/20176/27/20176/27/2017 8:54:12 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn...

rough ok to cover
p/s u/g n ok
ELE17-01537 Electrical Rough-In6/26/20176/27/20176/27/2017 8:25:16 AMAPASS
Ufer and site underground piping Phone #: ###-#### Inspection requested via web by Jeremy Cloud...

uffer last building, underground for lights, and feed off transformer to east building...ok to cover
ELE17-01976 Rough-In Permanent Service6/26/20176/27/20176/26/2017 1:28:03 PMACANC
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn Inspection cancelled from web by: Darryn Coburn