ELE06-00113
| Electrical Rough-In | 6/27/2006 | 6/28/2006 | 6/28/2006 4:45:15 PM | P | PART |
|
|
CONTACT: GREG PACK - CEILING INSPECTION LOBBY AREA; Phone #: ###-#### Internet Inspection Request from: Deb McCoy ceilings and walls anop ok to cover, misc floores
|
ELE06-02351
| Electrical Rough-In | 6/28/2006 | 6/28/2006 | 6/28/2006 4:44:27 PM | P | PASS |
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr made, ric ok
|
ELE06-00116
| Final | 6/27/2006 | 6/28/2006 | 6/28/2006 3:41:22 PM | P | CANC |
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles see conf
|
ELE06-00116
| Conference | 6/28/2006 | 6/28/2006 | 6/28/2006 3:40:58 PM | P | DONE |
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles met contr, air comp supplier, gen to discuss listing for air comp
|
ELE06-01722
| Electrical Rough-In | 6/28/2006 | 6/28/2006 | 6/28/2006 3:27:25 PM | P | PASS |
|
|
grounding grid inspection; Phone #: ###-#### Internet Inspection Request from: DJ Carman equipotential grid ok to pour only, called about seeing u/g
|
ELE05-00537
| Final | 6/28/2006 | 6/28/2006 | 6/28/2006 3:02:28 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Celinda Winters ok to final, signed card
|
ELE06-01060
| Final | 6/28/2006 | 6/28/2006 | 6/28/2006 1:30:52 PM | P | PASS |
|
|
chad; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
|
ELE06-00416
| Final | 6/28/2006 | 6/28/2006 | 6/28/2006 1:12:55 PM | P | PASS |
|
|
Re-inspect for final. (strapping at panel A, GFI at kitchen). Open boxes in small office are to be finished by city (low voltage guy). Generator has UL emblem on Katolight tag. Thank you Bob.; Phone #: ###-#### Internet Inspection Request from: todd hall ok to final, signed occ card
|
ELE06-00319
| Permanent Service | 6/26/2006 | 6/28/2006 | 6/28/2006 12:05:30 PM | A | PASS |
|
|
NEED INSPECTION ON SERVICE; Phone #: ###-#### Internet Inspection Request from: JENNY EMEL p/s u/g n ok
|
ELE06-02420
| Rough-In Permanent Service | 6/27/2006 | 6/28/2006 | 6/28/2006 10:57:57 AM | A | FAIL |
|
|
cynthia chandler ###-#### met owner, left corr notice, nec 250.56 single gec shall be augmented by additional electrode,110.12(A) unused openings shall be closed to afford substantially equivalent protection as wall of enclosure, 230.24(B)(2) service shall be min 12' above grade at lowest point, 408.4 circuit directory shall be complete and accurate, 250.64(C) gec shall be continuous, BCC approved set of plans shall be on job and available
|
ELE06-01095
| Final | 6/27/2006 | 6/28/2006 | 6/28/2006 10:27:12 AM | A | PASS |
|
|
door code is 0205; Phone #: ###-#### Internet Inspection Request from: Paul Schepper ok to final
|
ELE06-01097
| Final | 6/27/2006 | 6/28/2006 | 6/28/2006 10:25:30 AM | A | PASS |
|
|
door code is 0205; Phone #: ###-#### Internet Inspection Request from: Paul Schepper ok to final
|
ELE06-01096
| Final | 6/27/2006 | 6/28/2006 | 6/28/2006 10:00:12 AM | A | PASS |
|
|
door code is 0205; Phone #: ###-#### Internet Inspection Request from: Paul Schepper ok to final
|
ELE06-02423
| Final | 6/27/2006 | 6/28/2006 | 6/28/2006 9:51:06 AM | A | NR |
|
|
Phone #: ###-#### Internet Inspection Request from: Paul Schepper called, no adderss or sticker
|
ELE06-02422
| Final | 6/27/2006 | 6/28/2006 | 6/28/2006 9:50:36 AM | A | NR |
|
|
Phone #: ###-#### Internet Inspection Request from: Paul Schepper called, no address or sticker
|
ELE06-02411
| Final | 6/27/2006 | 6/28/2006 | 6/28/2006 8:51:22 AM | A | PASS |
|
|
jim; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley p/s o/h rec ok
|
ELE06-02359
| Rough-In Permanent Service | 6/23/2006 | 6/28/2006 | 6/28/2006 8:40:58 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Daryl DeGrange ric ok, p/s u/g n ok
|
ELE06-02396
| Rough-In Permanent Service | 6/27/2006 | 6/28/2006 | 6/28/2006 8:33:58 AM | A | PASS |
|
|
Joe; Phone #: ###-#### Internet Inspection Request from: Joseph Zumwalt ric ok p/s u/g n ok
|
ELE06-02291
| Rough-In Permanent Service | 6/26/2006 | 6/28/2006 | 6/28/2006 8:14:46 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 6/26/2006 at 11:07:09 AM. Contact: ###-####. ric ok, p/s u/g n ok
|
ELE06-02292
| Rough-In Permanent Service | 6/26/2006 | 6/28/2006 | 6/28/2006 8:13:04 AM | A | PASS |
|
|