PLM12-01313
| Plumbing Rough-in | 6/27/2012 | 6/28/2012 | 6/28/2012 3:29:36 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Erin Whiting
|
PLM12-01389
| Plumbing Rough-in | 6/27/2012 | 6/28/2012 | 6/28/2012 3:29:17 PM | P | PASS |
|
|
JOB # 16339. Phone #: ###-#### >> Inspection requested via web by Ann Marie Reyes
|
MEC12-01490
| Final | 6/27/2012 | 6/28/2012 | 6/28/2012 3:20:22 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Mike Almanza
|
PLM12-01468
| Sprinkler (Final) | 6/27/2012 | 6/28/2012 | 6/28/2012 3:19:45 PM | A | PASS |
|
|
>> Inspection requested via web by Kendall Hopkins
|
MEC12-01966
| Pressure Test | 6/27/2012 | 6/28/2012 | 6/28/2012 2:35:16 PM | P | PASS |
|
|
Please complete a pressure test inspection. If there are any questions/concerns, please contact Eric @ ###-#### (HR 2/20) Phone #: ###-#### >> Inspection requested via web by Jennifer Bryan-20 lb gas test pass
|
MEC12-01966
| Rough-in | 6/27/2012 | 6/28/2012 | 6/28/2012 2:34:30 PM | P | PASS |
|
|
Please complete a rough-in inspection. If there are any questions/concerns, please contact Eric @ ###-####. Phone #: ###-#### >> Inspection requested via web by Jennifer Bryan
|
PLM12-00371
| Final | 6/27/2012 | 6/28/2012 | 6/28/2012 2:10:57 PM | P | PEND |
|
|
Will final when fees hold is removed.
|
MEC12-00957
| Final | 6/28/2012 | 6/28/2012 | 6/28/2012 2:10:04 PM | P | PASS |
|
|
Please call with any questions or concerns. Thank you. Phone #: ###-#### >> Inspection requested via web by Jennifer Roy
|
MEC12-01928
| Rough-in | 6/28/2012 | 6/28/2012 | 6/28/2012 1:55:10 PM | P | FAIL |
|
|
duct blast test at 2pm on 6/28/12 Phone #: ###-#### >> Inspection requested via web by Debbie Marino-duct blast pass, no manual j on site.
|
MEC12-01928
| Pressure Test | 6/28/2012 | 6/28/2012 | 6/28/2012 1:54:29 PM | P | PASS |
|
|
duct blast test at 2pm on 6/28/12 Phone #: ###-#### >> Inspection requested via web by Debbie Marino
|
MEC12-02122
| Rough-in | 6/28/2012 | 6/28/2012 | 6/28/2012 1:27:54 PM | P | PART |
|
|
20 lb gas test pass. no changes to previous correction.
|
PLM12-00416
| Final | 6/28/2012 | 6/28/2012 | 6/28/2012 11:41:35 AM | P | PASS |
|
|
|
PLM11-01657
| Final | 6/27/2012 | 6/28/2012 | 6/28/2012 10:32:10 AM | A | PASS |
|
|
please call bill with any questions Phone #: ###-#### >> Inspection requested via web by Nicholas Paige
|
PLM12-00857
| Final | 6/27/2012 | 6/28/2012 | 6/28/2012 10:11:07 AM | A | PASS |
|
|
Call for garage code. ###-#### or ###-#### Phone #: ###-#### >> Inspection requested via web by David Stephenson
|
MEC12-02104
| Conference | 6/26/2012 | 6/28/2012 | 6/28/2012 9:55:59 AM | A | PASS |
|
|
PLEASE CALL ERIC BURRIS @ ###-#### 30 MINS BEFORE INSPECT, SO HE CAN MEET YOU AT HOUSE, THANKS SHANNON Phone #: ###-#### >> Inspection requested via web by Shannon Wells
|
MEC12-02104
| DOC - Permit Finaled | 6/28/2012 | 6/28/2012 | 6/28/2012 9:55:46 AM | P | PASS |
|
|
|
MEC12-02099
| Rough-in | 6/27/2012 | 6/28/2012 | 6/28/2012 9:45:52 AM | P | CANC |
|
|
3PM Duct blasting witness. Please confirm with Scott ###-#### >> Inspection requested via web by Stephanie Brown Inspection cancelled from web by: Stephanie Brown
|
MEC12-02122
| Rough-in | 6/27/2012 | 6/28/2012 | 6/28/2012 9:36:07 AM | A | FAIL |
|
|
If Dave isn''t available at ###-#### call Karen ###-#### or ###-####. Phone #: ###-#### >> Inspection requested via web by David Cole-need dampers, change undersized supplys and missing transfer grills. need to follow manual j.
|
PLM12-01474
| Groundwork | 6/27/2012 | 6/28/2012 | 6/28/2012 9:33:33 AM | A | PASS |
|
|
Please call when on your way, so I can arrive and let you in Phone #: ###-#### >> Inspection requested via web by Pat Falls
|