Inspections for the day of: Friday, June 28, 2013.
Number of inspections: 3
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorKimberly M. Johnson
TitleEROSION CONTROL
Phone #208-794-3958
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC13-00339 Conference6/27/20136/28/20136/28/2013 12:02:11 PMADONE
Met with Troy (owner's rep) and John (RP rep) and reviewed approved ECP. Reviewed action items neccessary to complete Phase I which required stabilization of the swales with seed and jute matting and installation of perimeter controls to protect the completed swales. Will re-inspect Monday.
ESC13-00232 BMP Violation6/25/20136/28/20136/28/2013 12:00:14 PMAPASS
ESC13-00144 General Inspection6/28/20136/28/20136/28/2013 12:00:00 AM FAIL
Still needs stabilized. Owner submitted mix design for seed, mulch and tackifier for approval that includes pasture mix seed at 50 lb/ac, 1500 lb/ac wood fiber mulch and 10 lb/ac soil pam for the tackifier. Trying to verify SoilPam application rate with manufacturer. Specification sheet provided doesn't spec application rates for this type of application. See email correspondance. LM for project owner 6/28