PLM16-02316
| Plumbing Rough-in | 6/28/2016 | 6/28/2016 | 6/29/2016 8:31:30 AM | P | PASS |
|
|
please call matt prior to arriving for access he will meet you onsite Phone #: ###-#### Inspection requested via web by Nicholas Paige >gw and tie in ok. >I talked to Rick at pw, said interceptor ok by engineer.
|
PLM16-01684
| Plumbing Rough-in | 6/28/2016 | 6/28/2016 | 6/28/2016 4:54:18 PM | P | PASS |
|
|
rough in moved to today per Mark phone call.
|
PLM16-02196
| Water Heater Final | 6/22/2016 | 6/28/2016 | 6/28/2016 4:06:26 PM | P | NH |
|
|
Home owner is Stan Mock please call him prior to arrival at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Maira Guzman >homeowner not home, want to reschedule for later date.
|
MIS16-00159
| PLM-Final | 6/27/2016 | 6/28/2016 | 6/28/2016 3:44:37 PM | P | PASS |
|
|
Binh Thanh// please call before- this inspection os for occupancy
|
PLM16-01561
| Plumbing Rough-in | 6/28/2016 | 6/28/2016 | 6/28/2016 2:18:13 PM | P | PASS |
|
|
if questions please contact Jerry @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann >bar water ri ok >basement gw vetns ri ok
|
PLM16-02286
| DOC - Permit Finaled | 6/28/2016 | 6/28/2016 | 6/28/2016 1:32:43 PM | P | PASS |
|
|
|
PLM16-02286
| Water and/or Sewer | 6/28/2016 | 6/28/2016 | 6/28/2016 1:32:23 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darren Wood
|
PLM16-00952
| Final | 6/27/2016 | 6/28/2016 | 6/28/2016 1:25:29 PM | P | PASS |
|
|
Please call ahead for access - Mark Phone #: ###-####
|
PLM16-01433
| Final | 6/27/2016 | 6/28/2016 | 6/28/2016 12:11:47 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kirk Johns
|
PLM16-02302
| Final | 6/27/2016 | 6/28/2016 | 6/28/2016 11:41:21 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tom Maxwell
|
GCP15-00194
| GCP-Final | 6/27/2016 | 6/28/2016 | 6/28/2016 11:35:48 AM | A | PASS |
|
|
Dan ###-####
|
PLM16-02080
| Final | 6/27/2016 | 6/28/2016 | 6/28/2016 10:51:58 AM | A | FAIL |
|
|
THIS IS FOR THE STARBUCKS. MEL IS THE CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER *Starbucks inside Fred Meyer* >support vertical copper drops every 10' and provide a mid story guide for pvc drop per table 3-2 >add hanger on 3" pvc horizontal vent before drop. >add hanger on 3/4" copper water lines at tie in point so its supported every 6' per table 3-2 >run condensate drain from condenser seperate from ice bin drain to avoid contaminating the ice. >need airgap on r/o drain and softener drain. >need to verify airgap on ice maker and missing coffee equipment.
|
PLM16-02080
| Plumbing Rough-in | 6/27/2016 | 6/28/2016 | 6/28/2016 10:45:53 AM | A | PASS |
|
|
THIS IS THE PHARMACY. MEL IS THE CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER >pharmacy ri ok
|
PLM16-02305
| Water Heater Final | 6/27/2016 | 6/28/2016 | 6/28/2016 9:49:08 AM | A | FAIL |
|
|
Zach is tenant please call to make sure he is home. Phone #: ###-#### Inspection requested via web by ron pierce >water heater pan needs to terminate outside instead into the crawl. send pic when complete.
|
PLM16-02304
| Other | 6/27/2016 | 6/28/2016 | 6/28/2016 9:32:12 AM | A | FAIL |
|
|
Jim-Gas Pressure Phone #: ###-#### >pressure test fail, needs to be 20lbs on a 30lb gauge for low pressure. >3/4 flex connector will not feed 400,000 btu's >stop work order put on job until proper permits are pulled for building, plumbing (water)and mechanical for pool heater.
|
PLM16-02312
| DOC - Permit Finaled | 6/28/2016 | 6/28/2016 | 6/28/2016 8:32:05 AM | P | PASS |
|
|
|
PLM16-02312
| Water and/or Sewer | 6/28/2016 | 6/28/2016 | 6/28/2016 8:31:53 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM16-02300
| DOC - Permit Finaled | 6/28/2016 | 6/28/2016 | 6/28/2016 8:20:51 AM | P | PASS |
|
|
|
PLM16-02300
| Water and/or Sewer | 6/27/2016 | 6/28/2016 | 6/28/2016 8:20:44 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM16-02299
| DOC - Permit Finaled | 6/28/2016 | 6/28/2016 | 6/28/2016 8:20:24 AM | P | PASS |
|
|
|
PLM16-02299
| Water and/or Sewer | 6/27/2016 | 6/28/2016 | 6/28/2016 8:20:17 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM16-00153
| PLM-Aging Inspection | 6/28/2016 | 6/28/2016 | 6/28/2016 8:04:59 AM | | FAIL |
|
|
no insp requested.
|
PLM16-00166
| PLM-Aging Inspection | 6/28/2016 | 6/28/2016 | 6/28/2016 8:04:16 AM | | PART |
|
|
wip
|