ELE16-03529
| Electrical Rough-In | 6/28/2017 | 6/28/2017 | 6/28/2017 2:04:08 PM | P | PASS |
|
|
Dining, activity, barista, salon Phone #: ###-#### Inspection requested via web by Bryan Atkins..
junction boxes over offices complete, areas as marked dated on plans...ok to cover
|
ELE17-01570
| Final | 6/28/2017 | 6/28/2017 | 6/28/2017 12:50:23 PM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by Christian Kilpatrick...
not ready for final...will need to schedule for next day
|
ELE17-01570
| Electrical Rough-In | 6/27/2017 | 6/28/2017 | 6/28/2017 12:49:32 PM | P | PASS |
|
|
Electrician: George Stanton Phone #: ###-#### Inspection requested via web by Christian Kilpatrick...
standard equipment...UL listings provided..plans on sight...ok
|
ELE17-02053
| Temporary Service | 6/28/2017 | 6/28/2017 | 6/28/2017 12:29:45 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn...
t/s u/g n ok
|
ELE17-01937
| Permanent Service | 6/28/2017 | 6/28/2017 | 6/28/2017 12:09:58 PM | A | PASS |
|
|
Late AM for inspection. Service upgrade for spa. Phone #: ###-#### Inspection requested via web by Rowdy Monroe...
p/s u/g rec ok
|
ELE17-01937
| Electrical Rough-In | 6/28/2017 | 6/28/2017 | 6/28/2017 12:09:34 PM | P | PASS |
|
|
Late AM for inspection. Service upgrade for spa. Phone #: ###-#### Inspection requested via web by Rowdy Monroe...
circuit for freezers and circuit for hot tub....hot tub hook up will be done on seperate permit
|
ELE17-01109
| Final | 6/28/2017 | 6/28/2017 | 6/28/2017 10:35:20 AM | P | PASS |
|
|
Key is under small rock to right of front stair Phone #: ###-#### Inspection requested via web by Jason Wicks...
permit was only for remodelling kitchen, laundry, and 2 bathrooms...added grounding on service only...ok to final
|
ELE13-02103
| Final | 6/28/2017 | 6/28/2017 | 6/28/2017 10:04:19 AM | P | PASS |
|
|
ok to final
|
ELE17-01842
| Final | 6/27/2017 | 6/28/2017 | 6/28/2017 10:00:24 AM | A | PASS |
|
|
Call Steve at ###-#### with any questions. Thank You Phone #: ###-#### Inspection requested via web by Steve Blackmer...
correction made...ok to final
|
ELE17-01969
| Conference | 6/26/2017 | 6/28/2017 | 6/28/2017 9:36:00 AM | A | PASS |
|
|
Kelly Phone #: ###-####...
discussed new bath requirements, gave him frequently asked questions paperwork, knowledgeable in work being performed
|
ELE17-00182
| Final | 6/27/2017 | 6/28/2017 | 6/28/2017 9:10:44 AM | A | FAIL |
|
|
code 8199 Phone #: ###-#### Inspection requested via web by Neal Rumsey...
1. missing plate on switches at fireplace 2. all bath outlets shall have GFI protection...outlets within 6ft of sink shall have GFI protection...outlet down low in mst bath 3. exposed romex shall have protection from physical damage...under kitchen sink 4. D/W shall be hooked up and operational 5. OCPD on A/C is to large
|
ELE17-02039
| Final | 6/28/2017 | 6/28/2017 | 6/28/2017 8:18:31 AM | P | PASS |
|
|
Brent Phone #: ###-####...
ok to final
|
ELE17-02039
| Permanent Service | 6/27/2017 | 6/28/2017 | 6/28/2017 8:18:12 AM | A | PASS |
|
|
Brent Phone #: ###-####...
p/s ok to reconnect
|
ELE17-01872
| Electrical Rough-In | 6/27/2017 | 6/28/2017 | 6/27/2017 2:05:26 PM | A | CANC |
|
|
Electrician: Preston Seay Phone #: ###-#### >> Inspection requested via web by Christian Kilpatrick Inspection cancelled from web by: Christian Kilpatrick
|