Inspections for the day of: Thursday, June 28, 2018.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-00680 Final6/27/20186/28/20186/29/2018 2:24:37 PMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace final ok
MEC18-02845 Final6/27/20186/28/20186/28/2018 4:06:00 PMPPASS
Please inspect late PM. We are doing corrections in AM. Phone #: ###-#### Inspection requested via web by Mary LaFayette- furance co ok- correcions made
MEC18-02968 Final6/28/20186/28/20186/28/2018 3:30:35 PMPFAIL
Phone #: ###-#### Inspection requested via web by Aaron Alandt- primary pvc drain needs 6" clearance to single wall flue- need to provide 14x8 combusion air in door that communicates with family room 1 high 1 low wih in 12" of ceiling and floor
MEC18-03025 Final6/27/20186/28/20186/28/2018 3:07:34 PMPPASS
INSTALLER AL ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
MEC18-03055 Rough-in6/28/20186/28/20186/28/2018 2:44:34 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak- insulation shield needs to be 1" cleance to bvent to small- need framing completed around b vent main level??? and firestop installed at ceiling- need access framed in for acces to furnace in attic or extend platform all the way to master closet access 24" wide minimum- R/A and supply air need to be insulated and secured- condensate needs nail plates and hangers installed- need make up air for range hood- coil and furnace do no match manual J on sizing and brand installed- left correction notice fron window
MEC18-03055 Pressure Test6/28/20186/28/20186/28/2018 2:36:56 PMPCANC
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass
MEC18-03048 Pressure Test6/28/20186/28/20186/28/2018 1:58:11 PMPFAIL
can you call with a half hour heads up Phone #: ###-#### Inspection requested via web by Nat Golden- gauge won zero out
MEC18-02665 Rough-in6/28/20186/28/20186/28/2018 1:36:40 PMPFAIL
Phone #: ###-#### Inspection requested via web by Debbie Marino- duct tape is not acceptable end cap- need to remove outside air tap from R/A register and seal or install metal round end cap and seal where flex was removed from and rerouted
MEC18-02548 Final6/22/20186/28/20186/28/2018 1:05:03 PMPPASS
Please call Steve Curtin at ###-#### prior to inspection. Phone #: ###-#### Inspection requested via web by Mary LaFayette- a/c co ok
MEC18-02891 Final6/26/20186/28/20186/28/2018 11:44:14 AMAPASS
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 10:00 AM . Contact for Right Now is Mary ###-####


Phone #: ###-#### Inspection requested via web by Mary LaFayette- 5lb flue pass- furnace a/c coil co ok
MEC18-02871 Final6/25/20186/28/20186/28/2018 11:08:47 AMAPASS
BRENT ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- furnace a/c coil co ok
MEC18-02928 Final6/26/20186/28/20186/28/2018 10:42:11 AMAPASS
PLEASE CALL CUSTOMER BEFORE HEADING OUT.

THANKS

MARY JANE Phone #: ###-#### Inspection requested via web by Trina DeBoard- a/c coil co ok
MEC18-03008 Rough-in6/27/20186/28/20186/28/2018 9:52:41 AMAPASS
ANDY ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
MEC18-02878 Final6/27/20186/28/20186/28/2018 9:26:28 AMAPASS
Home owner has to leave for work @ 10 am. Could you please try to get to before then. Thank you!!! Unit is #22 Inspection requested via web by Margie Rowe- electric furnace a/c coil ok
MEC18-02538 Final6/27/20186/28/20186/28/2018 8:50:03 AMAPASS
Please call Pat when on the way. We need to try to get out in the AM. ###-#### Thank you! Phone #: ###-#### Inspection requested via web by Rick Borg- corrections made
MEC18-03040 Card not on site to sign6/28/20186/28/20186/28/2018 8:48:45 AMAPASS
no card to sign
MEC18-03040 Final6/27/20186/28/20186/28/2018 8:48:01 AMAPASS
Please call Dustin, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum- final ok
MEC16-05382 Mec-Aging Inspection6/28/20186/28/20186/28/2018 8:01:11 AM FAIL
needs called in for inspection
MEC17-01951 Mec-Aging Inspection6/28/20186/28/20186/28/2018 8:00:38 AM FAIL
needs inspection called in by contractor
MEC18-02928 Final6/26/20186/28/20186/26/2018 10:24:50 AMACANC
PLEASE CALL CUSTOMER BEFORE HEADING THERE. Phone #: ###-#### >> Inspection requested via web by Trina DeBoard Inspection cancelled from web by: Trina DeBoard