MEC18-00680
| Final | 6/27/2018 | 6/28/2018 | 6/29/2018 2:24:37 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace final ok
|
MEC18-02845
| Final | 6/27/2018 | 6/28/2018 | 6/28/2018 4:06:00 PM | P | PASS |
|
|
Please inspect late PM. We are doing corrections in AM. Phone #: ###-#### Inspection requested via web by Mary LaFayette- furance co ok- correcions made
|
MEC18-02968
| Final | 6/28/2018 | 6/28/2018 | 6/28/2018 3:30:35 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Aaron Alandt- primary pvc drain needs 6" clearance to single wall flue- need to provide 14x8 combusion air in door that communicates with family room 1 high 1 low wih in 12" of ceiling and floor
|
MEC18-03025
| Final | 6/27/2018 | 6/28/2018 | 6/28/2018 3:07:34 PM | P | PASS |
|
|
INSTALLER AL ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
|
MEC18-03055
| Rough-in | 6/28/2018 | 6/28/2018 | 6/28/2018 2:44:34 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- insulation shield needs to be 1" cleance to bvent to small- need framing completed around b vent main level??? and firestop installed at ceiling- need access framed in for acces to furnace in attic or extend platform all the way to master closet access 24" wide minimum- R/A and supply air need to be insulated and secured- condensate needs nail plates and hangers installed- need make up air for range hood- coil and furnace do no match manual J on sizing and brand installed- left correction notice fron window
|
MEC18-03055
| Pressure Test | 6/28/2018 | 6/28/2018 | 6/28/2018 2:36:56 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass
|
MEC18-03048
| Pressure Test | 6/28/2018 | 6/28/2018 | 6/28/2018 1:58:11 PM | P | FAIL |
|
|
can you call with a half hour heads up Phone #: ###-#### Inspection requested via web by Nat Golden- gauge won zero out
|
MEC18-02665
| Rough-in | 6/28/2018 | 6/28/2018 | 6/28/2018 1:36:40 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino- duct tape is not acceptable end cap- need to remove outside air tap from R/A register and seal or install metal round end cap and seal where flex was removed from and rerouted
|
MEC18-02548
| Final | 6/22/2018 | 6/28/2018 | 6/28/2018 1:05:03 PM | P | PASS |
|
|
Please call Steve Curtin at ###-#### prior to inspection. Phone #: ###-#### Inspection requested via web by Mary LaFayette- a/c co ok
|
MEC18-02891
| Final | 6/26/2018 | 6/28/2018 | 6/28/2018 11:44:14 AM | A | PASS |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 10:00 AM . Contact for Right Now is Mary ###-####
Phone #: ###-#### Inspection requested via web by Mary LaFayette- 5lb flue pass- furnace a/c coil co ok
|
MEC18-02871
| Final | 6/25/2018 | 6/28/2018 | 6/28/2018 11:08:47 AM | A | PASS |
|
|
BRENT ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- furnace a/c coil co ok
|
MEC18-02928
| Final | 6/26/2018 | 6/28/2018 | 6/28/2018 10:42:11 AM | A | PASS |
|
|
PLEASE CALL CUSTOMER BEFORE HEADING OUT.
THANKS
MARY JANE Phone #: ###-#### Inspection requested via web by Trina DeBoard- a/c coil co ok
|
MEC18-03008
| Rough-in | 6/27/2018 | 6/28/2018 | 6/28/2018 9:52:41 AM | A | PASS |
|
|
ANDY ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
|
MEC18-02878
| Final | 6/27/2018 | 6/28/2018 | 6/28/2018 9:26:28 AM | A | PASS |
|
|
Home owner has to leave for work @ 10 am. Could you please try to get to before then. Thank you!!! Unit is #22 Inspection requested via web by Margie Rowe- electric furnace a/c coil ok
|
MEC18-02538
| Final | 6/27/2018 | 6/28/2018 | 6/28/2018 8:50:03 AM | A | PASS |
|
|
Please call Pat when on the way. We need to try to get out in the AM. ###-#### Thank you! Phone #: ###-#### Inspection requested via web by Rick Borg- corrections made
|
MEC18-03040
| Card not on site to sign | 6/28/2018 | 6/28/2018 | 6/28/2018 8:48:45 AM | A | PASS |
|
|
no card to sign
|
MEC18-03040
| Final | 6/27/2018 | 6/28/2018 | 6/28/2018 8:48:01 AM | A | PASS |
|
|
Please call Dustin, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum- final ok
|
MEC16-05382
| Mec-Aging Inspection | 6/28/2018 | 6/28/2018 | 6/28/2018 8:01:11 AM | | FAIL |
|
|
needs called in for inspection
|
MEC17-01951
| Mec-Aging Inspection | 6/28/2018 | 6/28/2018 | 6/28/2018 8:00:38 AM | | FAIL |
|
|
needs inspection called in by contractor
|
MEC18-02928
| Final | 6/26/2018 | 6/28/2018 | 6/26/2018 10:24:50 AM | A | CANC |
|
|
PLEASE CALL CUSTOMER BEFORE HEADING THERE. Phone #: ###-#### >> Inspection requested via web by Trina DeBoard Inspection cancelled from web by: Trina DeBoard
|