Inspections for the day of: Thursday, June 28, 2018.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02580 ELE-Aging Inspection6/28/20186/28/20186/29/2018 3:41:07 PM CANC
too busy
ELE13-03180 ELE-Aging Inspection6/28/20186/28/20186/29/2018 3:37:21 PM FAIL
waiting on contractor
ELE18-00575 Final6/27/20186/28/20186/28/2018 3:16:24 PMPPASS
Please contact Greg if you have questions. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker...corrections made...ok to final
ELE18-02407 Final6/28/20186/28/20186/28/2018 2:58:35 PMPFAIL
Final for circuit for new speed oven.
Contact Matt Hannum
Thank you, Phone #: ###-#### Inspection requested via web by Tom Betty...

all receptacles shall have GFCI protection in kitchen...210.8(B)
ELE18-01328 Final6/28/20186/28/20186/28/2018 2:18:39 PMPPASS
garage code 2018 Phone #: ###-#### Inspection requested via web by Darryn Coburn..ok to final
ELE18-02298 Electrical Rough-In6/28/20186/28/20186/28/2018 1:42:25 PMPPASS
Wall inspection for cover. Later in the afternoon would be great... Phone #: ###-#### Inspection requested via web by Sean Patton...ok to cover...using existing circuits wiring open walls where required outlets needed...ceiling wiring fished in
ELE18-02405 Permanent Service6/27/20186/28/20186/28/2018 12:26:28 PMAPASS
Mich Phone #: ###-####...perm service reconnect already...emergency replacement caused by overhead power lines hit...further work needs done before final...washer, dryer, and range circuits being replaced with ground...line set for A/C being relocated so not trip hazard in front of panel...hose bib preexisting and allowed to stay-undo money cost on homeowner...service grounding updated, new meter main, O/H replaced...ok
ELE18-01727 Electrical Rough-In6/27/20186/28/20186/28/2018 12:00:17 PMAFAIL
Ron Phone #: ###-####...
some corrections were completed...remaining

1. complete all make up to ceiling boxes and install exhaust fans with connector
2. seperate bathrooms from same circuit...outlets only can be tied together in bathrooms...put lighting for each bathroom on nearest circuit
3. veify smoke detector hard wiring and where need added..Ron will discuss with building inspector
ELE18-02420 Electrical Rough-In6/27/20186/28/20186/28/2018 10:40:45 AMAPASS
Access to patio is on left side of house Phone #: ###-#### Inspection requested via web by Terry Scott...ok to cover
ELE18-02376 Rough-In Permanent Service6/27/20186/28/20186/28/2018 10:20:03 AMAPASS
Phone #: ###-#### Inspection requested via web by Todd Hall...rough ok to cover...p/s u/g new ok
ELE18-02375 Rough-In Permanent Service6/27/20186/28/20186/28/2018 10:19:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Todd Hall...rough ok to cover...p/s u/g new ok
ELE18-02423 Conference6/27/20186/28/20186/28/2018 9:41:18 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton...discussed existing circuits and pipes that are attached to roof deck, oked to leave, not pulling new circuits in them, using them for existing heating units...conference rm layout, # outlets, location, and floor outlet requirement...tie wire marking and number on lighter LED fixtures
ELE18-01440 Electrical Rough-In6/27/20186/28/20186/28/2018 8:48:46 AMAPASS
Andy- rough in for ceilings Phone #: ###-####...ok to cover ceiling
ELE12-02616 ELE-Aging Inspection6/28/20186/28/20186/28/2018 7:49:36 AM PASS
permit expired
ELE12-02616 DOC - Permit Expired6/28/20186/28/20186/28/2018 7:49:13 AMAPASS
Electrical contractor works out of state and has been contacted multiple times
ELE18-01820 Final6/27/20186/28/20186/27/2018 1:19:56 PMAPASS
Ready now Phone #: ###-#### Inspection requested via web by Bob Glenn...ok to final
ELE18-01544 Final6/27/20186/28/20186/27/2018 1:19:28 PMAPASS
Ready now Phone #: ###-#### Inspection requested via web by Bob Glenn...ok to final