MEC18-03006
| Final | 6/28/2018 | 6/29/2018 | 6/29/2018 3:57:14 PM | P | PASS |
|
|
Nanci-homeower and she would like you to call her with an approx neet time Phone #: ###-####- furnace a/c coil co ok
|
MEC18-02992
| Final | 6/26/2018 | 6/29/2018 | 6/29/2018 3:40:56 PM | P | PASS |
|
|
INSTALLER JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
|
MEC18-00951
| Final | 6/29/2018 | 6/29/2018 | 6/29/2018 3:22:14 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Matthew BLANKENSHIP- need to resubmit manual J for furnace installed at residence- range hood does not meet manufactures minimum clearance for gas appiliances- need tp seal dryer duct where penetrates ion to box in laundry room
|
MEC18-00928
| Final | 6/29/2018 | 6/29/2018 | 6/29/2018 2:57:00 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- intake air for furnace not installed per manufactures recommendations for snow load/ grade above ground
|
MEC18-02836
| Final | 6/29/2018 | 6/29/2018 | 6/29/2018 2:34:11 PM | P | PASS |
|
|
Please call ###-#### prior to inspection Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
|
MEC18-03056
| Final | 6/28/2018 | 6/29/2018 | 6/29/2018 2:18:17 PM | P | NR |
|
|
Late PM. Rob ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- per phone call with Rob- will reschedule
|
MEC18-03058
| Final | 6/28/2018 | 6/29/2018 | 6/29/2018 1:42:38 PM | P | PART |
|
|
Chris ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- mini split and bath exhaust ok- will final permit out when electrical permit is issued
|
MEC18-03048
| Final | 6/29/2018 | 6/29/2018 | 6/29/2018 1:23:41 PM | P | PASS |
|
|
|
MEC18-03048
| Pressure Test | 6/29/2018 | 6/29/2018 | 6/29/2018 1:23:09 PM | P | PASS |
|
|
Things should be proper this time:) Phone #: ###-#### Inspection requested via web by Nat Golden- 20lb gas pass- co ok
|
MEC18-00928
| Final | 6/28/2018 | 6/29/2018 | 6/29/2018 11:27:19 AM | A | FAIL |
|
|
LATE AM PLZ Phone #: ###-#### Inspection requested via web by Oleg Chervak- corrections still not made
|
MEC18-01905
| Final | 6/28/2018 | 6/29/2018 | 6/29/2018 11:19:21 AM | A | FAIL |
|
|
Access 3711 Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- arma flex at stucco location needs to be continous see bare copper and seal penetration- need air balance and duct blast tests completed- need drip leg on furnace and water heater between shut off valve and appliance- seal dryer vent penetration in washer closet where dryer duct comes into box
|
MEC18-01304
| Final | 6/26/2018 | 6/29/2018 | 6/29/2018 10:59:01 AM | A | FAIL |
|
|
please call when you are on the way. Customers name is Delores and her number is ###-#### Phone #: ###-#### Inspection requested via web by Marisa Hone- need to witness flue pressure test
|
MEC18-03049
| Final | 6/28/2018 | 6/29/2018 | 6/29/2018 10:45:50 AM | A | NR |
|
|
Diane is homeowner, Kelly Buel is lead install for HVAC, his number is ###-#### if you have any questions. Phone #: ###-#### Inspection requested via web by kelly Martin- need to pressure test gas line and add to permit and pay fee- need combustion air in door high and low 14x8- need drip leg between shut off valve and appliance- seal linset penetration outside
|
MEC18-01595
| Rough-in | 6/28/2018 | 6/29/2018 | 6/29/2018 10:22:39 AM | A | PART |
|
|
Cover inspection. call thad prior to arriving for access Phone #: ###-#### Inspection requested via web by Nicholas Paige- north end of builing seal ok- ok to insulate- will need inspection called in when roof curbs are installed and ducts connected and to check insulation- will need to pull tiles in other phase at final to verify that flex to registers is good tile was put in without and inspection
|
MEC18-02976
| Final | 6/28/2018 | 6/29/2018 | 6/29/2018 10:11:32 AM | A | NH |
|
|
Please call Steve prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- called # listed no answer- went by no one home
|
MEC17-05258
| Final | 6/29/2018 | 6/29/2018 | 6/29/2018 9:49:32 AM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown- flue on furnave need 1/4" grade to furnace has trap at wye branch- need insulation shield installed garage ceiling and maintain 1" clearance to combustibles and trim ring installed on b vent after framing is completed
|
MEC18-01022
| Final | 6/29/2018 | 6/29/2018 | 6/29/2018 9:47:41 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown- final ok
|
MEC18-00761
| Final | 6/29/2018 | 6/29/2018 | 6/29/2018 9:47:15 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown- water heater flue needs 1/4" grade has trap at wye branch- need to finish arma flex in garage bare copper exposed
|
MEC18-00039
| Final | 6/29/2018 | 6/29/2018 | 6/29/2018 9:46:12 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Sam Brown- final ok
|
MEC18-02917
| Final | 6/28/2018 | 6/29/2018 | 6/29/2018 9:30:52 AM | A | PASS |
|
|
Please give a 30 minute windows Phone #: ###-#### Inspection requested via web by Tyler Collado- furnace a/c coil co ok
|
MEC18-02363
| Final | 6/22/2018 | 6/29/2018 | 6/29/2018 9:13:35 AM | P | CANC |
|
|
Please inspect early PM if possible. Homeowner David Francke ###-#### Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
|
MEC18-02999
| Pressure Test | 6/26/2018 | 6/29/2018 | 6/29/2018 8:45:28 AM | A | CANC |
|
|
Call Jack at ###-#### to coordinate Phone #: ###-#### Inspection requested via web by Sabrina DeHority- no needed
|
MEC18-02999
| Final | 6/26/2018 | 6/29/2018 | 6/29/2018 8:45:12 AM | A | PASS |
|
|
Call Jack at ###-#### to coordinate Phone #: ###-#### Inspection requested via web by Sabrina DeHority- furnace a/c coil co ok
|
MEC18-02353
| Rough-in | 6/29/2018 | 6/29/2018 | 6/29/2018 8:21:54 AM | A | PASS |
|
|
fireplace R/I ok
|
MEC18-02527
| Final | 6/29/2018 | 6/29/2018 | 6/29/2018 8:21:27 AM | A | PASS |
|
|
|
MEC18-01344
| Final | 6/28/2018 | 6/29/2018 | 6/29/2018 8:19:54 AM | A | PASS |
|
|
#1919 Phone #: ###-#### Inspection requested via web by Ashley Stegemann- fireplace final ok
|
MEC16-04040
| Mec-Aging Inspection | 6/29/2018 | 6/29/2018 | 6/29/2018 7:48:16 AM | | FAIL |
|
|
contractor needs o fix correction and call in final inspection
|
MEC17-03358
| Mec-Aging Inspection | 6/29/2018 | 6/29/2018 | 6/29/2018 7:47:25 AM | | FAIL |
|
|
contractor needs to schedule inspection
|
MEC16-01175
| Mec-Aging Inspection | 6/29/2018 | 6/29/2018 | 6/29/2018 7:46:37 AM | | DONE |
|
|
|
MEC16-01175
| DOC - Permit Expired | 6/29/2018 | 6/29/2018 | 6/29/2018 7:46:26 AM | A | PASS |
|
|
no return call
|