Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM17-03819 PLM-Aging Inspection6/29/20186/29/20187/2/2018 1:22:29 PM NR
wip
PLM18-02675 Final6/29/20186/29/20186/29/2018 4:12:21 PMPPASS
If you can, please inspect after 2:30. We are doing a flue test and meeting mechanical inspector there. If you can''t be there from 2:30 to 3 please call homeowner, Chuck Olson at ###-#### prior so he can meet you there. Phone #: ###-#### Inspection requested via web by Mary LaFayette
PLM18-02694 Water Heater Final6/28/20186/29/20186/29/2018 4:00:30 PMPPASS
Bradly-homeowner Phone #: ###-####
PLM18-02673 Final6/26/20186/29/20186/29/2018 3:44:54 PMPPASS
INSTALLER JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
PLM18-00752 Roof Drains6/28/20186/29/20186/29/2018 3:44:33 PMPPASS
ANDY IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
PLM18-02710 Sprinkler (Final)6/28/20186/29/20186/29/2018 3:23:59 PMPPASS
Phone #: ###-#### Inspection requested via web by Brett Rowland
PLM18-02736 Water Heater Final6/28/20186/29/20186/29/2018 2:58:06 PMPFAIL
Phone #: ###-#### Inspection requested via web by Vaughn Carlson,.
1. The water heater flue must be tested and witness by ahj.
2. MIP for the t&p must be metallic.
3. Mech contractor to pressure test the gas line.
PLM18-01228 Final6/28/20186/29/20186/29/2018 2:22:29 PMPFAIL
Phone #: ###-#### Inspection requested via web by TOBI WLSON.
1. The expansion tank is isolated from the water heater by the check valve. Install the e.t. on the wh side of the check.
2. Cell core pipe cannot be used on the water heater flue, only air intake side.
PLM18-02657 Water Heater Final6/26/20186/29/20186/29/2018 1:49:06 PMPPASS
Customer would like this inspection @1:00 pm. she will be at this house at that time. Please call customer when you''re on your way. Renate Huebner ###-#### Phone #: ###-#### Inspection requested via web by Kevin Smith
PLM18-02345 Final6/29/20186/29/20186/29/2018 12:01:27 PMAPASS
Phone #: ###-#### Inspection requested via web by Nels Moore
PLM18-01691 Final6/28/20186/29/20186/29/2018 11:49:12 AMAPASS
#19694
7373 enter Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM18-02157 Water Heater Final6/25/20186/29/20186/29/2018 11:16:13 AMAFAIL
Jessica Flicker is new owner ###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart
Improper burner function, orange flame. Notified contractor.
PLM18-02703 Other6/29/20186/29/20186/29/2018 10:47:55 AMAPASS
went over the materials and fittings required to run and tie in the pressurized sewer connection.
PLM18-02748 Water Heater Final6/28/20186/29/20186/29/2018 10:20:24 AMAPASS
Phone #: ###-#### Inspection requested via web by Chris Field
PLM18-02724 Water and/or Sewer6/29/20186/29/20186/29/2018 10:07:49 AMAPASS
Phone #: ###-#### Inspection requested via web by Brett Simmons
PLM18-02724 DOC - Permit Finaled6/29/20186/29/20186/29/2018 10:07:38 AMPPASS
PLM18-02590 DOC - Permit Finaled6/29/20186/29/20186/29/2018 10:07:24 AMPPASS
PLM18-02723 Water and/or Sewer6/29/20186/29/20186/29/2018 9:55:16 AMAPASS
Phone #: ###-#### Inspection requested via web by Brett Simmons
PLM18-02723 DOC - Permit Finaled6/29/20186/29/20186/29/2018 9:55:03 AMPPASS
PLM18-02073 Other6/28/20186/29/20186/29/2018 9:38:59 AMACANC
Water Service inspection. If questions call Chad @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann.
Was updated as a water service inspection.
PLM18-02073 Water and/or Sewer6/29/20186/29/20186/29/2018 9:38:34 AMPPASS
Water Service inspection. If questions call Chad @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann,
Pass the new water servoce for cover. The service runs to two buildings and will require double chedk valves at both locations.
The permit value will need to be updated.
PLM18-02751 Sprinkler (Final)6/28/20186/29/20186/29/2018 9:13:45 AMAPART
Chass Phone #: ###-####.
The PVB must be certified prior to final.
PLM18-02661 Other6/28/20186/29/20186/29/2018 9:00:56 AMAPASS
Luchini--- conference Phone #: ###-####
Advised on code and inspection requirments