ELE20-00872
| Final | 6/29/2020 | 6/29/2020 | 6/29/2020 1:52:12 PM | P | PASS |
|
|
Please give Kengei a 30 minute heads up before inspection to insure access Kengei''s phone number is ###-#### Phone #: ###-#### Inspection requested via web by Shaun Kirkman Final ok
|
ELE20-02191
| Permanent Service | 6/26/2020 | 6/29/2020 | 6/29/2020 12:24:58 PM | P | FAIL |
|
|
Power has been off for over a year. Phone #: ###-#### Inspection requested via web by Kendra Lanham Verify Grounding electrode system-if water pipe is used it shall be accompanied with a supplemental ground rod, If not 2 grounds shall be used
|
ELE20-01470
| Electrical Rough-In | 6/27/2020 | 6/29/2020 | 6/29/2020 11:52:45 AM | A | PASS |
|
|
3366 is code for the contractor box right of the main door. Phone #: ###-#### Inspection requested via web by Jack Cowan
Corrections fixed-Rough-in ok to cover
|
ELE19-04574
| Final | 6/26/2020 | 6/29/2020 | 6/29/2020 10:39:34 AM | A | PASS |
|
|
Call for lock box- Brian *screened* Phone #: ###-#### Final ok
|
ELE20-01435
| Final | 6/27/2020 | 6/29/2020 | 6/29/2020 10:06:08 AM | A | CANC |
|
|
Final. Contact Kory with questions Phone #: ###-#### Inspection requested via web by Kory Peterson Will re-schedule for wednesday the 1st for replacement of GFCI in bathroom due to sheetrock repair
|
ELE19-03582
| Final | 6/25/2020 | 6/29/2020 | 6/29/2020 9:31:20 AM | A | CANC |
|
|
screened // Greg Phone #: ###-#### Need W/R on exterior recept,GFCI protection for bath @ add receptacle within 36" of second vanity ,AFCI protection for bedroom where start of exisitng circut,Install bath vanity's
|
ELE20-01686
| Electrical Rough-In | 6/26/2020 | 6/29/2020 | 6/29/2020 9:06:18 AM | A | PASS |
|
|
We need an underground inspection. Nick is the site contact. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker Secondaries only at this time in South West sid ok to cover
|