Inspections for the day of: Wednesday, June 3, 2009.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTroy Cobbley
TitleFIRE INSPECTOR
Phone #794-9483
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD09-00721 FIRE-Final Inspection6/3/20096/3/20096/4/2009 3:33:58 PMPPASS
life safety passed
FIR09-00112 FIR-Aging Inspection6/3/20096/3/20096/4/2009 10:38:29 AM NR
Work is in progress
FIR09-00239 INSP-Sprinkler Rough-in/Hydro6/2/20096/3/20096/3/2009 2:40:14 PMAPASS
The overhead hydro test passed. All piping can be covered except the pipe just south of the main entrance due to insulation that is hanging from the roof deck acting as an obstruction to the attic sprinklers.
BLD09-00568 FIRE-Final Inspection6/2/20096/3/20096/3/2009 1:36:09 PMAFAIL
Repair the two existing exit signs and provide the additional exit sign as shown on the approved plans. All other items are ok. Per Bob Archibald the three thumbturn dead bolts between the warehouse and the showroom/office areas are ok to remain.
BLD09-00792 FIRE-Final Inspection6/2/20096/3/20096/3/2009 1:24:59 PMAPASS
Life safety passed. The deadbolt on the rear door was removed as I waited.
FIR07-01032 INSP-Final Inspection6/2/20096/3/20096/3/2009 9:59:26 AMAPASS
The sprinklers are complete in the new first floor exit passage way at the skilled nursing area.
BLD07-01846 FIRE-Final Inspection6/2/20096/3/20096/3/2009 9:58:35 AMAFAIL
This inspection was for two new entry areas Emergency lighting is required in the exit way. Atleast one fire extinguisher is required as discussed. An exit sign leading to the exit way is missing. The project related fire alarm for this area had issues as well See the city approved fire alarm plans for deficiancies. They include smoke detector and a door holder that are not shown on the plans. A door holder that is shown on the plans but has not been installed. A remote annunciator that has not been installed. A smoke detector that does not set off the general alarm. A room missing a strobe. A wall mount a/v has been revised to a ceiling mount and was the wrong candella. All of these items are in a very small area.
FIR08-00382 INSP-Alarm Testing6/3/20096/3/20096/3/2009 9:56:02 AMPFAIL
See the city approved plans for deficiancies. They include smoke detector and a door holder that are not shown on the plans. A door holder that is shown on the plans but has not been installed. A remote annunciator that has not been installed. A smoke detector that does not set off the general alarm. A room missing a strobe. A wall mount a/v has been revised to a ceiling mount and was the wrong candella. All of these items are in a very small area.