Inspections for the day of: Thursday, June 30, 2005.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01909 Electrical Rough-In6/30/20056/30/20056/30/2005 4:17:07 PMPPASS
james-- for the ceiling ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ceiling only ok to cover
ELE05-00336 Final6/30/20056/30/20056/30/2005 4:11:45 PMPPASS
HAD TO PULL A PERMIT TO GET AN INSPECTION SO WE COULD LET THE HOME SELLER KNOW WHAT NEEDED TO BE BROUGHT UP TO CODE..WE NEVER ENDED UP DOING ANY WORK.; Phone #: ###-#### Internet Inspection Request from: Tyler Bowen ok to final
ELE05-00760 Final6/29/20056/30/20056/30/2005 2:35:30 PMPFAIL
alan; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa called contr, left corr notice,408.4 ckt directory shall be specific,422.30 disc shall be supplied for water heater, BCC4-05-33 and 110.2 water heater shall be listed.
ELE05-02328 Rough-In Permanent Service6/30/20056/30/20056/30/2005 12:38:25 PMPNH
dan ###-#### they will recall
ELE05-01018 Final6/30/20056/30/20056/30/2005 12:35:18 PMPPASS
INSPECTION HAPPENED WITH FINAL OF BUILDING..NEED TO CLOSE OUT THIS PERMIT.; Phone #: ###-#### Internet Inspection Request from: Tyler Bowen ok to final
ELE05-02325 Permanent Service6/30/20056/30/20056/30/2005 12:10:39 PMPPASS
chuck; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa p/s u/g exst ok
ELE05-01619 Final6/29/20056/30/20056/30/2005 9:52:37 AMAFAIL
Call prior to inspection Internet Inspection Request from: Steve Craig called ncontr, left corr notice, 406.4 recpts shall be securely fastened, 408.4 circuit directory shall be provided for sub-panel, 110.2 boiler and steamer shall be listed
ELE05-01560 Final6/29/20056/30/20056/30/2005 9:11:02 AMAFAIL
Call Rob if this fails at ###-####; Phone #: ###-#### Internet Inspection Request from: KATHY WEIL called contr, left corr notice, 406.5,404.9 faceplates shall cover openings and seat against mounting surface,408.4 circuit directory shall be specific, 110.26(A)(2) panel shall have 30" wide work space, 422.16(B)(1)(2) disposal cord shall be max 3' long,210.8(A)(3) outdoor recpts shall be gfci, 314.21 sheetrock shall be repaired in util room for light, 210.70(A)(2)(a) light shall be in stairway
ELE05-01559 Final6/29/20056/30/20056/30/2005 9:01:34 AMAFAIL
Call Rob if this fails at ###-####; Phone #: ###-#### Internet Inspection Request from: KATHY WEIL called contr, left corr notice, 352.30(A) rnc shall be fastened within 3' of box,406.5,404.9 faceplates shall cover openings and seat against mounting surface, 110.26(A)(2) panel shall have 30" wide work space,210.8(A)(3) outdoor recpts shall have gfci, 422.16(A) disposal cord connector shall be tight,210.70(A)(2) light shall be in stairway, 408.4 circuit directory shall be specific