Inspections for the day of: Monday, June 30, 2008.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorForrest France
TitleFIRE INSPECTOR
Phone #794-1981
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
FIR08-00300 INSP-Final Inspection6/27/20086/30/20086/30/2008 4:27:24 PMANR
Reschedule for tomorrow, with fire alarm inspection. KR
FIR08-00018 INSP-Sprinkler Rough-in/Hydro6/27/20086/30/20086/30/2008 4:13:16 PMPPART
Inspection for the 5th floor OH rough-in only completed today, see 6 item list on approved plan set including seismic clearance, plumbing pipe supported by sprinkler pipe, be aware of possible light fixture obstructions, discussed relocation of one sw head at the west end unit, provide as-builts for minor field modifications/floor plan changes, rotate one sw head to vertical, standpipe needs proper seismic clearance or flex couplings within 1' on either side, discussed hydrostatic testing schedule for overhead work.
BLD08-00786 FIRE-Final Inspection6/30/20086/30/20086/30/2008 4:07:23 PMPPASS
Fire life safety finaled.
BLD08-00787 FIRE-Final Inspection6/30/20086/30/20086/30/2008 4:06:55 PMPPASS
Fire life safety inspection passed-per Forrest France Fir08-00399 covers Elam & Burke and vanilla finish///7-2-08 BAS
FIR08-00068 INSP-Sprinkler Rough-in6/27/20086/30/20086/30/2008 2:38:29 PMAFAIL
See annotations on plan for areas in need of revision including missing head coverage at a storage room, two missing armover hangers, three painted heads to be replaced, and one pendent cut too high. Remainder of overhead system modifications are good for cover at the drop ceilings.
FIR08-00312 INSP-Alarm Testing6/27/20086/30/20086/30/2008 1:10:30 PMPCANC
Talked with David and let him know that the sprinkler permit also needs to be called in for the fire alarm testing. He will call in both permits tomorrow for finals.KR
BLD07-02588 FIRE-Final Inspection6/26/20086/30/20086/30/2008 12:59:47 PMAPASS
Life safety passed. KR
BLD08-00705 FIRE-Final Inspection6/27/20086/30/20086/30/2008 12:40:58 PMAPASS
Fire life safety passed, fire sprinkler permit not required as no modifications necessary, noted door is not yet installed-verified hardware will be compliant per contractor.
FIR08-00394 INSP-Final Inspection6/27/20086/30/20086/30/2008 12:34:53 PMAPASS
Fire alarm test completed.KR
FIR08-00047 INSP-Final Inspection6/30/20086/30/20086/30/2008 12:00:42 PMPPART
Temp. okayed with D. Hanneman's permission pending completion of the elevator controls-no elevator use allowed until upgrade work is finished, tested and related fire alarm permit finaled.
FIR08-00385 INSP-Sprinkler Rough-in6/30/20086/30/20086/30/2008 11:57:57 AMPPART
OH fire sprinkler modifications are good for cover at the file storage room, C/N items verified for compliance.
BLD07-01932 FIRE-Final Inspection6/27/20086/30/20086/30/2008 11:56:07 AMAPART
Okay for temporary occupancy with D. Hanneman's permission pending completion of the elevator controls. NOTE: elevator power to be turned off and no use is allowed until work is completed and tested per Temporary Occ. conditions and agreement.
FIR08-00450 INSP-Final Inspection6/30/20086/30/20086/30/2008 11:43:58 AMPPASS
Noted corrections are complete, final fire alarm testing passed, permit finaled.
BLD07-00133 FIRE-Final Inspection6/27/20086/30/20086/30/2008 11:42:01 AMANR
Missing ceiling tile at several locations, project related fire sprinkler permit needs finaled, not ready for final fire life safety approval at this time.
BLD07-03107 FIRE-Final Inspection6/27/20086/30/20086/30/2008 11:40:18 AMAFAIL
Missing project related fire sprinkler permit final.
BLD08-00882 FIRE-Final Inspection6/27/20086/30/20086/30/2008 11:36:31 AMAPASS
Door hardware changed per Forrest last inspection. KR
FIR08-00182 INSP-Sprinkler Rough-in6/27/20086/30/20086/30/2008 8:44:48 AMPCANC
UG Flush Phone #: ###-#### x1234 Internet Inspection Request from: Alicia Pauley Inspection cancelled from web by: Alicia Pauley
FIR08-00093 INSP-Final Inspection6/30/20086/30/20086/30/2008 12:00:00 AMAPASS
Fire alarm testing completed.KR