Inspections for the day of: Tuesday, June 5, 2012.
Number of inspections: 4
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorClint A Smith
TitleEROSION CONTROL INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC12-00472 General Inspection6/5/20126/5/20126/5/2012 1:23:15 PM FAIL
Verbal to RP:
Due to the evidence of erosion occuring at the top of the gabion baskets at the banks of the pond, they must be procected with a structural control to devert flows away from the section where the erosion has occured. Will follow up on 6/7/2012am
ESC11-00879 General Inspection6/5/20126/5/20126/5/2012 1:22:30 PM FAIL
Written Correction Notice (message to RP):
Install sediment barriers along back of curb and sidewalks though out project area where the disturbed soils grade slopes towards back of sidewalks, curbs or gutter pans.
Install stormdrain inlet protection on all stormdrains interior and exterior where no protection is provided.

FAILURE TO COMPLY WITH THE NOTICE WITHIN THE GIVEN TIMEFRAME, WILL RESULT IN A STOP WORK ORDER.

Will re-inspect on 6/20/2012pm
ESC11-00687 Aging Inspection6/5/20126/5/20126/5/2012 7:50:29 AM PASS
ESC11-00716 Aging Inspection6/5/20126/5/20126/5/2012 7:41:49 AM PASS