ELE20-00506
| Final | 6/5/2020 | 6/5/2020 | 6/5/2020 1:23:40 PM | P | FAIL |
|
|
garage code 4224 Phone #: ###-#### Inspection requested via web by Troy Ballard 110.26 Work space required in front of meter. 210.52E3 Recep needed for garage patio
|
ELE20-01921
| Rough-In Permanent Service | 6/5/2020 | 6/5/2020 | 6/5/2020 12:26:58 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by jamie berg rough in ok p/s u/g n ok
|
ELE19-04658
| Rough-In Permanent Service | 6/5/2020 | 6/5/2020 | 6/5/2020 11:41:13 AM | P | PASS |
|
|
Service inspection Building #4. Thank you Phone #: ###-#### Inspection requested via web by Stuart Welton p/s u/g n ok
|
ELE19-01403
| Electrical Rough-In | 6/4/2020 | 6/5/2020 | 6/5/2020 11:40:48 AM | P | PASS |
|
|
Rough in inspection for boxes and raceways in slab 6-3. Phone #: ###-#### Inspection requested via web by John Mittleider 6 floor deck pour ok to cover Pics on file
|
ELE20-01919
| Electrical Rough-In | 6/4/2020 | 6/5/2020 | 6/5/2020 10:11:14 AM | A | PASS |
|
|
Call for access Phone #: ###-#### Inspection requested via web by John VanZandt Kitchen, Understairs, Bar, living room FP wall, Laundry, Up J&J Bath lighting, Down bed misc receps. ok to cover
|
ELE20-00363
| Final | 6/5/2020 | 6/5/2020 | 6/5/2020 10:02:55 AM | A | PASS |
|
|
Canceled by mistake final ok
|
ELE20-01910
| Final | 6/4/2020 | 6/5/2020 | 6/5/2020 9:41:42 AM | A | PASS |
|
|
Relocated 2 Air Conditioner disconnects. Tony is our contact at ###-#### Phone #: ###-#### Inspection requested via web by Kelly Felin Final ok
|
ELE20-01910
| Electrical Rough-In | 6/5/2020 | 6/5/2020 | 6/5/2020 9:41:30 AM | P | PASS |
|
|
Relocated 2 Air Conditioner disconnects. Tony is our contact at ###-#### Phone #: ###-#### Inspection requested via web by Kelly Felin Mini split and A/C disc. rough in ok
|
ELE20-00943
| Final | 6/4/2020 | 6/5/2020 | 6/5/2020 9:16:42 AM | A | FAIL |
|
|
Please call Kevin ###-#### with a heads up to meet you there. If you have any questions please feel free to contact Jason ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan 356.12(1) LFMC shall not be ran where exposed to physical damage. (Seal tight accross walk way to tub) 680.26B7. All metal parts within 5ft of tub shall be bonded to tub. (Remove or bond 1in emt to tub) 334.1 NM cable shall terminate in box(14-2 hanging in basement near door way. 110.3 Dead recep in crawl next to door way
|