Inspections for the day of: Tuesday, June 6, 2006.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-01980 Electrical Rough-In6/5/20066/6/20066/6/2006 4:25:09 PMPPASS
We need a wall inspection ; Phone #: ###-#### Internet Inspection Request from: DJ Carman walls only, soffit, and u/g ok to cover
ELE06-00457 ELE-Aging Inspection6/6/20066/6/20066/6/2006 4:01:25 PM DONE
suc
ELE06-00456 ELE-Aging Inspection6/6/20066/6/20066/6/2006 3:54:51 PM DONE
suc
ELE06-01442 Final6/6/20066/6/20066/6/2006 3:27:16 PMPPASS
Scheduled by a contractor via Hello! on 6/6/2006 at 7:50:04 AM. Contact: ###-####. ok to final
ELE06-02071 Permanent Service6/6/20066/6/20066/6/2006 2:49:49 PMPFAIL
bill ###-#### called contr left corr notice,nec 300.5 u/g cable shall be 24" deep, 312.5 abrasion protection shall be provided forr all conductors entering enclosures, 314.15(A) fittings installed in wet locations shall be listed for use in wet locations,BCC no cover shall be done prior to inspection
ELE06-02067 Temporary Service6/6/20066/6/20066/6/2006 1:53:20 PMPPASS
brian ###-#### t/s u/g n ok
ELE06-02025 Temporary Service6/5/20066/6/20066/6/2006 1:31:27 PMAPASS
verna; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley t/s u/g n ok
ELE05-04387 Final6/6/20066/6/20066/6/2006 12:53:56 PMPNR
Scheduled by a contractor via Hello! on 6/6/2006 at 8:48:09 AM. looked at electrical and told that we can not do final inspection without core inspection at earlier or same time.Told builder about no listing for audio cabinet and light box. Told to get blanks for lites, strap conduit, address, disposal not wired , ground wire at service shall be strapped
ELE05-04207 Final6/5/20066/6/20066/6/2006 11:54:08 AMAFAIL
The pump has been replaced and we are ready for final re-inspection. Contact is Loren @ ###-####. Thanks; Phone #: ###-#### Internet Inspection Request from: Steve Syltie called, left message, no correction written, but left message stating no pump there and to call when done
ELE06-02057 Electrical Rough-In6/5/20066/6/20066/6/2006 10:53:41 AMAFAIL
WE ARE READY FOR A ROUGH-IN FOR COVER FOR THE THEATER AND EQUIPMENT ROOM. THE PANEL IS NOT READY FOR INSPECTION AT THIS TIME. WE WOULD LIKE TO HAVE THE OK TO COVER IN THE THEATER ROOM WHILE WE COMPLETE THE SUB-PANEL. THE STORE DOES NOT OPEN UNTIL 10:00 AM, YOU CAN ASK FOR GREG NETTLES OR CRAIG ADAMS AT THE STORE.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH called contr, left corr notice, 300.4(A)&(D) edge of holes and cables and raceways shall be 1 1/4" from edge of framing members, 352 & 362 there shall be not more than 4 quarter bends in raceway between pull points,BCC no u/g shall be covered before inspection
ELE06-02062 Rough-In Permanent Service6/5/20066/6/20066/6/2006 9:59:18 AMAPASS
Please call if there are any problems ; Phone #: ###-#### Internet Inspection Request from: Kevin Blackmon ric ok, ps u/g n ok
ELE06-02063 Rough-In Permanent Service6/5/20066/6/20066/6/2006 9:56:28 AMAPASS
Please call if there are any questions or problems Thanks; Phone #: ###-#### Internet Inspection Request from: Kevin Blackmon ric ok, p/s u/g n ok
ELE06-01306 Final6/5/20066/6/20066/6/2006 8:51:33 AMAFAIL
TIM; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, left corr notice, nec 406.5 recpt faceplates shall seat against mounting surface, 210.70(A)(2) there shall be a wall switch at each level for stairs and lights shall work
ELE06-02029 Temporary Service6/5/20066/6/20066/6/2006 8:20:23 AMAPASS
Scheduled by a contractor via Hello! on 6/5/2006 at 12:59:04 PM. Contact: ###-####. t/s u/g n ok
ELE06-02031 Temporary Service6/5/20066/6/20066/6/2006 8:18:52 AMAPASS
Scheduled by a contractor via Hello! on 6/5/2006 at 1:00:32 PM. Contact: ###-####. t/s u/g n ok
ELE06-02030 Temporary Service6/5/20066/6/20066/6/2006 8:18:04 AMAFAIL
Scheduled by a contractor via Hello! on 6/5/2006 at 12:59:42 PM. Contact: ###-####. called contr, left message, nec 110.12(C) there shall be no broken parts(grounded electrode terminal bar)
ELE06-02060 Electrical Rough-In6/5/20066/6/20066/6/2006 8:13:14 AMAPASS
###-#### - LLOYD called, left message, ric ok