ELE12-00530
| ELE-Aging Inspection | 6/6/2013 | 6/6/2013 | 6/6/2013 4:01:21 PM | | DONE |
|
|
contractor to call for final
|
ELE12-00194
| ELE-Aging Inspection | 6/6/2013 | 6/6/2013 | 6/6/2013 3:50:51 PM | | DONE |
|
|
waiting on owner
|
ELE13-01411
| Electrical Rough-In | 6/6/2013 | 6/6/2013 | 6/6/2013 3:41:10 PM | P | PASS |
|
|
call Art with questions Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack Corrections made. Rough in ok cover
|
ELE13-01428
| Temporary Service | 6/6/2013 | 6/6/2013 | 6/6/2013 3:30:13 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Jim Williams t/s o/h n ok
|
ELE13-01432
| Permanent Service | 6/6/2013 | 6/6/2013 | 6/6/2013 3:01:20 PM | P | FAIL |
|
|
Marcus Tam Phone #: ###-#### As per NEC and BCC- For permenant service 2 sources of ground required. BCC requires an electrical contractor to perform work on any dwelling larger than 2 family.
|
ELE11-02529
| ELE-Aging Inspection | 6/6/2013 | 6/6/2013 | 6/6/2013 2:23:34 PM | | DONE |
|
|
Still under construction
|
ELE11-02597
| ELE-Aging Inspection | 6/6/2013 | 6/6/2013 | 6/6/2013 2:04:31 PM | | DONE |
|
|
Still waiting on owner
|
ELE13-01401
| Permanent Service | 6/6/2013 | 6/6/2013 | 6/6/2013 1:49:45 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Jim Williams p/s o/h rec ok
|
ELE13-01307
| Electrical Rough-In | 6/6/2013 | 6/6/2013 | 6/6/2013 1:32:09 PM | P | PART |
|
|
Ceiling inspection, existing conduits, and lighting. Cover inspection on small pony wall at serving counter. Please call Mike 1/2 hour prior to inspection. Phone #: ###-#### >> Inspection requested via web by Mike Basye Ceiling Fail BCC Section4-05-32 Code violation not to be retained- When altering a pre-existing electrical wire, equiptment, apparatus, or fixture, or adding any new wiring, the existing electrical wiring in close proximity shall be in accordance with the present code. BCC Section 4-05-23 Unlawful to conceal- It shall be unlawful for any person to cover up or in any way conceal any electrical wiring, cables, conduits,or other equiptment until the same has been inspected and approved by an electrical inspector. 1/2 wall kitchen rough in ok cover
|
ELE13-01427
| Electrical Rough-In | 6/6/2013 | 6/6/2013 | 6/6/2013 1:01:41 PM | P | PASS |
|
|
please inspect garage Phone #: ###-#### >> Inspection requested via web by ERIC CENTERS Garage addition rough in ok cover
|
ELE13-00877
| Rough-In Permanent Service | 6/5/2013 | 6/6/2013 | 6/6/2013 12:37:26 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Bob Glenn Rough in ok cover p/s u/g n ok
|
ELE13-00017
| Electrical Rough-In | 6/5/2013 | 6/6/2013 | 6/6/2013 12:12:50 PM | A | PASS |
|
|
3 rooms of floor heat. 25sq. ft ea. per discussion on 6/5 with Rock sometime between 10:30 - 1pm. Phone #: ###-#### >> Inspection requested via web by mike brown 3rd floor bath rooms floor heat rough in ok cover
|
ELE13-01380
| Electrical Rough-In | 6/5/2013 | 6/6/2013 | 6/6/2013 10:51:42 AM | A | PASS |
|
|
steve has the special key to allow the elevator to get to the 2nd floor, call him when on the way for him to meet you there. thanks Phone #: ###-#### >> Inspection requested via web by Don Lustig wall rough in ok cover
|
ELE13-01392
| Permanent Service | 6/6/2013 | 6/6/2013 | 6/6/2013 10:18:01 AM | P | PASS |
|
|
mike Phone #: ###-#### p/s u/g n ok
|
ELE13-01153
| Electrical Rough-In | 6/5/2013 | 6/6/2013 | 6/6/2013 10:06:49 AM | A | NH |
|
|
call before for access// Laura Phone #: ###-#### called left message
|
ELE13-01426
| Final | 6/6/2013 | 6/6/2013 | 6/6/2013 10:00:56 AM | A | CANC |
|
|
please call to let me know you are coming so the homeowner can let you in. thanks Phone #: ###-#### >> Inspection requested via web by Eddy Udry Needed rough in inspection
|
ELE13-01426
| Electrical Rough-In | 6/6/2013 | 6/6/2013 | 6/6/2013 9:56:41 AM | P | PASS |
|
|
please call to let me know you are coming so the homeowner can let you in. thanks Phone #: ###-#### >> Inspection requested via web by Eddy Udry Rough in ok cover
|
ELE13-01298
| Rough-In Permanent Service | 6/6/2013 | 6/6/2013 | 6/6/2013 9:34:53 AM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI 1. Torn sheathing 14-2 above panel. repair/ repace. 2. Torn sheathing 14-2 up bath light. Repair/ replace. 3. Up bath 12-2 above receptical secured less than 1 1/4" from surface of framing member. 4. Protect wiring within 6' of up stairs attic access. 5. Bond metal tab in all 3/0 boxes.
|
ELE13-00498
| Electrical Rough-In | 6/5/2013 | 6/6/2013 | 6/6/2013 8:53:44 AM | A | NH |
|
|
Contact: Andy Eckhart.... Walls, underground and ceiling inspections please Phone #: ###-#### >> Inspection requested via web by Deb Gooden Called left message
|