Inspections for the day of: Thursday, June 6, 2013.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01408 Electrical Rough-In6/6/20136/6/20136/6/2013 3:19:50 PMPPASS
Call Jeff 30 minutes in advance for access. Phone #: ###-#### >> Inspection requested via web by Clint Tate rough-in ok cover floor box and conduits
ELE13-00320 Final6/6/20136/6/20136/6/2013 3:05:32 PMPPASS
Terry Cushing is contact ###-####. Phone #: ###-#### >> Inspection requested via web by Debby Ellis final ok
ELE13-01429 Final6/6/20136/6/20136/6/2013 2:42:06 PMPFAIL
wiring for new ductless heat pump, any question call ###-#### Phone #: ###-#### >> Inspection requested via web by Andy Rose NEC400.8 flexible cords and cables shall not be used as a substitute for fixed wiring of a structure
ELE13-00498 Electrical Rough-In6/6/20136/6/20136/6/2013 2:15:45 PMPPASS
rough-in ok cover walls in N.work area,hard lid in man trap rms,ceiling grid in grid operatipons
ELE13-01400 Electrical Rough-In6/6/20136/6/20136/6/2013 1:45:16 PMPPASS
please call me if you have any questions thanks Shaun ###-#### Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman rough-in ok cover kitchen,dinning,family strairwell
ELE13-01050 Conference6/5/20136/6/20136/6/2013 1:26:41 PMADONE
Conference with Carl Petteck to identify and discuss code requirements. Phone #: ###-#### >> Inspection requested via web by Scott Campbell Discuussed requirements of code violations of exsisting electrical piping. If exsposed and in the area of electrical remodel, has to be brought up to 2008 code
ELE12-02735 Conference6/5/20136/6/20136/6/2013 10:04:29 AMADONE
Bud on site. Conference to discuss sheet rocking one side of exam room walls. Phone #: ###-#### >> Inspection requested via web by Clint Tate Discussed need to hang sheet to install cable trays, one side ok only in areas of cable tray.
ELE13-00886 Final6/5/20136/6/20136/6/2013 9:52:44 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Phil Baker final ok
ELE13-01409 Electrical Rough-In6/5/20136/6/20136/6/2013 9:39:45 AMAPASS
walls please Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin rough-in ok cover walls
ELE13-01396 Temporary Service6/6/20136/6/20136/6/2013 9:18:08 AMAPASS
Requesting a temporary service inspection.
The contact number is for Bob Thomas. Phone #: ###-#### >> Inspection requested via web by Dan Hardisty t/s o/h n ok
ELE12-02680 Final6/5/20136/6/20136/6/2013 8:40:42 AMAPASS
andrew Phone #: ###-#### final ok
ELE13-01408 Electrical Rough-In6/5/20136/6/20136/6/2013 8:26:28 AMANH
Jeff is contact. Phone #: ###-#### >> Inspection requested via web by Clint Tate No access,no answer by contact person,no address
ELE13-01013 Rough-In Permanent Service6/5/20136/6/20136/6/2013 8:03:28 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Joe Thomas rough-in p/s u/g n ok
ELE13-01278 Final6/5/20136/6/20136/5/2013 2:23:15 PMAPASS
Phone #: ###-#### >> Inspection requested via web by shane vigil correction of service panel clearance completed at time of final inspection