Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02817 ELE-Aging Inspection6/6/20166/6/20166/13/2016 10:41:08 AM CANC
too busy
ELE16-01023 Rough-In Permanent Service6/6/20166/6/20166/6/2016 3:46:30 PMPPASS
Phone #: ###-#### Inspection requested via web by TOM BICANDI
rough-in ok cover p/s u/g n ok
ELE16-01771 Rough-In Permanent Service6/6/20166/6/20166/6/2016 3:31:13 PMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn
rough-in ok cover p/s u/g n ok
ELE16-01782 Electrical Rough-In6/6/20166/6/20166/6/2016 2:51:20 PMPPASS
Please call Matt for access ###-#### Phone #: ###-#### Inspection requested via web by Emmet Bushman
Rough-in on two outlets ok
ELE16-00570 Electrical Rough-In6/6/20166/6/20166/6/2016 2:23:16 PMPPASS
UG Cover. Von is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen
Underground for secondary feeds to building ok cover
ELE16-01773 Final6/6/20166/6/20166/6/2016 2:04:10 PMPFAIL
Joe Phone #: ###-####
110.9 available fault current calculation required proir
110.16 Arc flash hazard warning required
400.5 #6 soo cord is rated at 45 amp not 50
ELE16-00796 Final6/6/20166/6/20166/6/2016 1:25:03 PMPFAIL
Key is by back door on top of the patio roof Phone #: ###-#### Inspection requested via web by Jason Wicks
406.5 receptacles shall be rigidly mounted
406.4 tamper resistant receptacles required
ELE16-01759 Temporary Service6/6/20166/6/20166/6/2016 1:09:04 PMPPASS
Need another one as we had to fix something. Phone #: ###-#### Inspection requested via web by Vicki Moore
correction fixed t/s o/h n ok
ELE16-01788 Permanent Service6/6/20166/6/20166/6/2016 1:08:13 PMPPASS
Daniel// please call before Phone #: ###-####
t/s o/h rec ok 1 meter needed
ELE16-01671 Temporary Service6/6/20166/6/20166/6/2016 12:48:52 PMPPASS
Phone #: ###-#### Inspection requested via web by Eric Schroeder
t/s o/h n ok
ELE16-01791 Temporary Service6/6/20166/6/20166/6/2016 12:32:43 PMPPASS
Phone #: ###-#### Inspection requested via web by Chris Berthelot
t/s u/g n ok
ELE16-01684 Electrical Rough-In6/6/20166/6/20166/6/2016 12:17:54 PMPCANC
Garage rough in. Thank you Phone #: ###-#### Inspection requested via web by Eric Brown
not ready at this time
ELE16-01759 Temporary Service6/3/20166/6/20166/6/2016 10:14:00 AMAFAIL
Call Travis with any questions Phone #: ###-#### Inspection requested via web by Vicki Moore
240.24 no over current device shall be located higher then 6'-7"
100 amp breaker not rated where it is installed
110.26 shall maintain 36"working clearences in front of panel
need address changed to 1550 W idaho street
ELE16-01727 Rough-In Permanent Service6/3/20166/6/20166/6/2016 9:17:20 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn
Rough-in ok cover p/s u/g n ok
ELE16-01777 Temporary Service6/5/20166/6/20166/6/2016 9:08:30 AMAPASS
Phone #: ###-#### Inspection requested via web by David Nelson
t/s u/g n ok
ELE16-01745 Final6/5/20166/6/20166/6/2016 8:22:52 AMAPASS
underground conduit for shop Phone #: ###-#### Inspection requested via web by Mark Morgan
needed r/i











ELE16-01745 Electrical Rough-In6/6/20166/6/20166/6/2016 8:22:35 AMPPASS
underground conduit for shop Phone #: ###-#### Inspection requested via web by Mark Morgan
Underground fro detached shop ok cover
ESC15-00354 Site Final6/6/20166/6/20166/6/2016 8:15:24 AMPPASS
site final
ESC15-00353 Site Final6/6/20166/6/20166/6/2016 8:14:53 AMPPASS
site final ok
ELE15-04080 Final6/6/20166/6/20166/6/2016 8:13:56 AMAPASS
Phone #: ###-#### Inspection requested via web by cal crosby
Final ok