BLD15-04512
| BLD-Final | 6/6/2016 | 6/6/2016 | 6/7/2016 7:53:42 AM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by Antonio Carone
|
BLD15-03500
| BLD-Final | 6/6/2016 | 6/6/2016 | 6/7/2016 7:53:12 AM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by Antonio Carone
|
BLD15-04511
| BLD-Final | 6/6/2016 | 6/6/2016 | 6/7/2016 7:52:55 AM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by Antonio Carone
|
BLD16-01161
| BLD-Framing/Rough-in | 6/6/2016 | 6/6/2016 | 6/6/2016 3:17:39 PM | P | NR |
|
|
Call prior to going Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane. Needs plum bing.
|
BLD16-01164
| BLD-Framing/Rough-in | 6/6/2016 | 6/6/2016 | 6/6/2016 3:16:50 PM | P | PASS |
|
|
Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane
|
BLD16-01163
| BLD-Energy code compliance | 6/6/2016 | 6/6/2016 | 6/6/2016 3:03:16 PM | P | PASS |
|
|
As late as possible Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane
|
BLD16-01163
| BLD-Framing/Rough-in | 6/6/2016 | 6/6/2016 | 6/6/2016 3:03:01 PM | P | PASS |
|
|
Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane
|
BLD16-01162
| BLD-Energy code compliance | 6/3/2016 | 6/6/2016 | 6/6/2016 3:02:45 PM | P | PASS |
|
|
Phone #: 2085015747 >> Inspection requested via mobile web by Tom
|
BLD14-03071
| BLD-Framing/Rough-in | 6/6/2016 | 6/6/2016 | 6/6/2016 2:32:09 PM | P | PART |
|
|
Pat Phone #: ###-####. Framing inspection 1st. to third floors north half only. Neeeds to complete all fireblocking, interior straping, provide listing for washer boxes and door frames in corridor and complete LSL blocking on 2nd floor and continue OSB sheathing on interior shear walls to roof deck and brace them per plans. ok to insulate these areas only.
|
BLD16-01268
| BLD-Wall Bracing | 6/6/2016 | 6/6/2016 | 6/6/2016 1:22:47 PM | P | PASS |
|
|
Zane Phone #: ###-####
|
BLD14-00804
| BLD-Conference | 6/3/2016 | 6/6/2016 | 6/6/2016 10:42:50 AM | A | CANC |
|
|
Danny Phone #: ###-####. Needs to speak with Jim Sly regaurding inspections.
|
GCB15-00133
| GCB-Shearwall | 5/31/2016 | 6/6/2016 | 6/6/2016 9:47:15 AM | A | NR |
|
|
Mike ###-####. Work in progress, not ready. Will need to reschedule.
|
BLD16-01163
| BLD-Framing/Rough-in | 6/3/2016 | 6/6/2016 | 6/6/2016 9:09:15 AM | A | FAIL |
|
|
Phone #: 2085015747 >> Inspection requested via mobile web by Thomas Lane. Foam seal all plumbing penetrations at top and bottom plates and under tubs. Correction notice posted. Ok to insulate.
|
BLD15-01921
| BLD-Other | 6/2/2016 | 6/6/2016 | 6/6/2016 8:37:50 AM | A | PASS |
|
|
would like call ahead; Brian Phone #: ###-####. base layer of 5/8 type x rock for roof/ceiling assembly ok.
|