Inspections for the day of: Tuesday, June 6, 2017.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-01511 Electrical Rough-In6/6/20176/6/20176/6/2017 3:02:41 PMPPASS
Doug Phone #: ###-####
2nd permit exists for sanctuary and upstairs area ELE14-02605.
Foyer, family room, offices, and bathrooms walls and hardlids rough in ok cover.
ELE17-01708 Electrical Rough-In6/6/20176/6/20176/6/2017 2:29:25 PMPPASS
Call half hour before // Mike Phone #: ###-####
Asked general contractor to call on if smoke detectors required, none added at time of RI inspection. Spare beds, and bath not remodelled. Living, kitchen, master bed and bath and basement rough in ok cover.
ELE15-04089 Final6/6/20176/6/20176/6/2017 1:36:31 PMPPASS
Contact Craig Timmons
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek
Early underground only permit. Final ok
ELE17-00739 Electrical Rough-In6/5/20176/6/20176/6/2017 1:34:32 PMPPASS
2nd floor ceiling rough in lobby Phone #: ###-#### Inspection requested via web by JENNY EMEL
Elevator lobby grid rough in ok cover
ELE17-01443 Rough-In Permanent Service6/5/20176/6/20176/6/2017 10:50:20 AMAFAIL
Contact is Todd Sellman ###-#### Phone #: ###-#### Inspection requested via web by Todd Sellman
Check individual inspections for RI and PS.
ELE17-01443 Permanent Service6/6/20176/6/20176/6/2017 10:15:52 AMPFAIL
Contact is Todd Sellman ###-#### Phone #: ###-#### Inspection requested via web by Todd Sellman
110.24- Available fault current shall be posted prior to permanent service inspection.
352.6- All PVC pipe and fittings shall be listed. Cantex 1 piece expansion joint not listed as shown on manufactureres web sight.
ELE17-01443 Electrical Rough-In6/6/20176/6/20176/6/2017 10:11:45 AMPPASS
Contact is Todd Sellman ###-#### Phone #: ###-#### Inspection requested via web by Todd Sellman
Underground rough in ok cover
ELE17-01727 Final6/5/20176/6/20176/6/2017 9:56:19 AMAFAIL
Please call the office, one of us will have to meet you there, for access. ###-####, Thank You!!! Phone #: ###-#### Inspection requested via web by Clay Morgan
210.8- All garage receptacle outlets shall have GFCI protection
ELE17-01727 Electrical Rough-In6/5/20176/6/20176/6/2017 9:53:26 AMAPASS
Please call the office, one of us will have to meet you there, for access. ###-####, Thank You!!! Phone #: ###-#### Inspection requested via web by Clay Morgan
Shop has minimum required, exterior light at man door, 1 interior light, 1 double duplex receptacle, and 1 exterior receptacle, 1 100 amp panel with 2 ground rods.
Underground rough in ok cover
ELE17-00578 Final6/6/20176/6/20176/6/2017 9:05:39 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M
Final ok
ELE17-01301 Permanent Service6/5/20176/6/20176/5/2017 3:00:39 PMACANC
contact paul wheeler Phone #: ###-#### >> Inspection requested via web by Deb Gooden Inspection cancelled from web by: Deb Gooden