Inspections for the day of: Wednesday, June 6, 2018.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-00900 Electrical Rough-In6/6/20186/6/20186/6/2018 2:19:25 PMPNH
This Inspection will be for the underground leading into the building from the pool. Thank you. Phone #: ###-#### Inspection requested via web by Craig Korell
All gates locked contact unable to reach responcible party for access. Will recall
ELE17-01337 Electrical Rough-In6/5/20186/6/20186/6/2018 1:33:51 PMPPASS
Requesting rough inspection of the bar area Phone #: ###-#### Inspection requested via web by Clint Tate
Bar wall rough in ok cover
ELE18-01907 Rough-In Permanent Service6/4/20186/6/20186/6/2018 10:56:36 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn
Rough in ok cover p/s u/g n ok
ELE18-01936 Temporary Service6/6/20186/6/20186/6/2018 10:50:51 AMPFAIL
Temp service energized. Stopped to check GFCI protection.
590.6(B)- Receptacles other than 120 volt used for temp power shall have GFCI protection. 250 did not trip when tested.
ELE18-02011 Electrical Rough-In6/5/20186/6/20186/6/2018 10:12:43 AMAPASS
Please call Lynn prior to arrival. Phone #: ###-#### Inspection requested via web by Lynn Proctor
Wall rough in ok cover
ELE17-04193 Final6/5/20186/6/20186/6/2018 9:52:02 AMAPASS
Matt. Call prior to heading to site. Phone #: ###-#### Inspection requested via web by Sean DeLacy
No Card posted. Final ok
ELE18-01470 Final6/5/20186/6/20186/6/2018 9:17:46 AMAPART
Final For Third 3
Request for TCO
Please call Corey Phone #: ###-#### Inspection requested via web by Kevin Perez
Level 3 only TCO ok
ELE18-01789 Permanent Service6/5/20186/6/20186/6/2018 8:37:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Don Conley
Underground being installed at time of inspection. p/s u/g n ok
ELE18-02113 Temporary Service6/5/20186/6/20186/6/2018 8:07:27 AMAFAIL
Phone #: ###-#### Inspection requested via web by Neal Rumsey
250.24- Service shall have a grounding electrode connected to the grounded conductor. Main bonding jumper needed to complete bonding as per 250.28.
Sent a picture message to contact