Inspections for the day of: Thursday, June 7, 2007.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01763 Final6/7/20076/7/20076/7/2007 3:21:43 PMPPASS
corrections are done Phone #: ###-#### Internet Inspection Request from: HARVEY REYNA ok survey posted called 406.8 inuse covers
ELE07-02055 Electrical Rough-In6/6/20076/7/20076/7/2007 2:34:19 PMPPART
rick; Phone #: ###-#### Internet Inspection Request from: Victoria u/g between blds ok
ELE07-01947 Temporary Service6/7/20076/7/20076/7/2007 2:02:21 PMPPASS
Temporary Power - Thank you!! (overhead) Phone #: ###-#### Internet Inspection Request from: Tracy Robertson
t/s o/h new ok
ELE06-03162 Final6/7/20076/7/20076/7/2007 1:35:14 PMPFAIL
key in outlet box by man door. Internet Inspection Request from: Shane Vigil
corr. new violations created, 110.3(B) & 314.3 manufactures instructions , and metallic flex not allowed in plastic boxes,
BCC wiring shall be remove if box is blacked off where fiis removed in MB closet
ELE07-01265 Electrical Rough-In6/7/20076/7/20076/7/2007 12:55:50 PMPPART
concrete cover for electrode ok
ELE07-01264 Rough-In Permanent Service6/6/20076/7/20076/7/2007 12:45:37 PMAPASS
Journeyman on site; Gene ###-####. Thank you!
Phone #: ###-#### Internet Inspection Request from: Tracy Robertson
r/i p/s u/g new ok
ELE07-01482 Permanent Service6/6/20076/7/20076/7/2007 11:00:17 AMAFAIL
Robert; Phone #: ###-#### Internet Inspection Request from: Hattie James
called corr, not made still needs to remove bush, and stump
ELE07-02058 Electrical Rough-In6/6/20076/7/20076/7/2007 10:31:12 AMAPASS
bryan ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok
ELE07-02058 Final6/7/20076/7/20076/7/2007 10:30:51 AMAPASS
bryan ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok
ELE07-02060 Rough-In Permanent Service6/6/20076/7/20076/7/2007 10:07:47 AMAFAIL
alan; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang corr called210.52(A&B) needs recept outlet kit wall by pantry, 312.5 no SER allowed in conduit out of bottom of panel, 334.23 protect cables by attic access, 334.30 remove cable loop and staple within 12" vacuum outlets, 314.17(C) replace all 2,3,4, gang boxes with broken out factory clamps,
ELE06-02704 Electrical Rough-In6/6/20076/7/20076/7/2007 8:53:30 AMAPART
Please inspect "ceiling cover" on all 3 floors of C-wing. Thank you. Phone #: ###-#### Internet Inspection Request from: Jim Friend ok anop
ELE07-02054 Permanent Service6/6/20076/7/20076/6/2007 2:37:26 PMAPASS
###-#### - dan p/s o/h rec. ok