Inspections for the day of: Thursday, June 7, 2007.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorWilliam E Thomas
TitleELE-INSPECTOR
Phone #794-9492
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-02053 Conference6/6/20076/7/20076/7/2007 4:28:38 PMPDONE
michael ###-####-- call 1st before insp
the owner was in nampa when I called. He had no direct questions and said he was familiar with what was needed and would schedule a confrence when he actually had some work done for us to look at.
ELE07-01194 Final6/7/20076/7/20076/7/2007 4:13:50 PMPPASS
Owners should be home. If not key code at front door is 1290. Phone #: ###-#### Internet Inspection Request from: David Nelson
final ok
ELE07-00594 Final6/7/20076/7/20076/7/2007 3:25:07 PMPPASS
Call the electrical contractor, Dave Weil if this doesn''t pass for some reason, Thanks Mike! Phone #: ###-#### Internet Inspection Request from: KATHY WEIL
final ok
ELE07-01586 Final6/7/20076/7/20076/7/2007 2:27:31 PMPPART
final again thank you
Chirs Sirani contact ###-#### Phone #: ###-#### Internet Inspection Request from: Debby Ellis
1. temp occcu approved
2. the low voltage cables and junction box above the buisness managers offices must be done according to the NEC.
ELE07-02066 Temporary Service6/7/20076/7/20076/7/2007 1:47:07 PMPPASS
glen; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang
t/s o/h n ok
ELE07-02041 Rough-In Permanent Service6/6/20076/7/20076/7/2007 1:07:07 PMPPASS
Please call Dan at ###-#### with any questions. Thanks. Phone #: ###-#### Internet Inspection Request from: Raj Sandou
1.ri ok
2. p/s o/h n ok
ELE07-00648 Conference6/6/20076/7/20076/7/2007 12:09:08 PMADONE
Conference with builder, electrician and inspector for island outlets. Please call to let us know what time. Thanks Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot
ELE07-00648 Final6/7/20076/7/20076/7/2007 11:52:40 AMPPASS
Conference with builder, electrician and inspector for island outlets. Please call to let us know what time. Thanks Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot
final ok--per survey note-210.52 counter recep locations
ELE07-00893 Final6/6/20076/7/20076/7/2007 11:50:12 AMAPASS
Butch; Phone #: ###-#### Internet Inspection Request from: Hattie James
final ok
ELE07-01861 Final6/6/20076/7/20076/7/2007 10:59:35 AMAPASS
Please call so I can meet you over there. Thanks, Dick Phone #: ###-#### Internet Inspection Request from: Richard Jones
final ok
ELE07-01861 Rough-In Permanent Service6/7/20076/7/20076/7/2007 10:11:58 AMPPASS
Please call so I can meet you over there. Thanks, Dick Phone #: ###-#### Internet Inspection Request from: Richard Jones
p/s o/h reconnect ok
ELE07-00552 Final6/6/20076/7/20076/7/2007 10:11:12 AMAPASS
Please call so I can meet you over there. Thanks, Dick Phone #: ###-#### Internet Inspection Request from: Richard Jones
final ok
ELE06-04706 Final6/6/20076/7/20076/7/2007 9:27:46 AMAFAIL
Please call so I can meet you over there. Thanks, Dick Phone #: ###-#### Internet Inspection Request from: Richard Jones
should be a roughin inspection not final,
work still under way
ELE06-04706 Electrical Rough-In6/7/20076/7/20076/7/2007 8:52:41 AMPFAIL
Please call so I can meet you over there. Thanks, Dick Phone #: ###-#### Internet Inspection Request from: Richard Jones
work not completed, suc.
ELE07-01586 Final6/6/20076/7/20076/7/2007 8:41:28 AMAFAIL
Chris Sirani contact final Thank-You Phone #: ###-#### Internet Inspection Request from: Debby Ellis
1. low voltage cables dangeling through the cieling
2. no cover plates on the receps and switches.