Inspections for the day of: Thursday, June 7, 2012.
Number of inspections: 21
Percentage of inspections complete: 95 %
Percentage of inspections not complete: 5 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC12-00514 Site Preparation6/4/20126/4/2012   
ELE12-00848 Final6/6/20126/7/20126/7/2012 3:36:48 PMAPASS
>> Inspection requested via web by Stephanie White
ELE12-00847 Final6/6/20126/7/20126/7/2012 3:36:37 PMAPASS
>> Inspection requested via web by Stephanie White
ELE12-01303 Electrical Rough-In6/7/20126/7/20126/7/2012 3:06:55 PMPPASS
tom gilbert, contact, ###-####, thanks Phone #: ###-#### >> Inspection requested via web by Debby Ellis u/g conduit ok
ELE12-01305 Rough-In Permanent Service6/7/20126/7/20126/7/2012 3:06:16 PMPPASS
Phone #: ###-#### >> Inspection requested via web by steve cooper r/i p/s u/g new ok
ELE12-00671 Electrical Rough-In6/7/20126/7/20126/7/2012 2:41:31 PMPCANC
Eric Phone #: ###-#### grid ceiling ok
ELE12-01349 Final6/7/20126/7/20126/7/2012 2:41:05 PMPPASS
ELE12-01348 Final6/7/20126/7/20126/7/2012 2:40:51 PMPPASS
Please do a pm inspection so IP will turn power on. Please call Kyle @ ###-#### or Andy @ ###-#### Phone #: ###-#### >> Inspection requested via web by Amie Rose
ELE12-01340 Temporary Service6/7/20126/7/20126/7/2012 2:39:51 PMPPASS
power allowed on t/s basis only, owner has 3 months to correct all wiring done in violation of prior and current N.E.C. per acti ng PDS director Hal Simmons. #!230.6 service entrance conductors shall be installed outside of building, or encased in 2"of concrete or brick, #2 230.70(A)(1) shall install service disconnect either outside of a building,or nearest the point of entrance of the service conductors ( back to back) #3 250.24 (A)(5) shall isolated grounding, and neutrals load side of service main, inside panel shall be addressed as subpanel. #4 250.134,250.138 shall provide 4wire branch circuit, receptacle, and pigtail for range and dryer fed from subpanel #5 250.24 all main grounding and bonding conductors shall connect to the neutral service conductor bus at the main service , not subpanel

t/s o/h rec. ok
ELE12-01335 Final6/7/20126/7/20126/7/2012 1:56:16 PMPPASS
ELE12-01335 Permanent Service6/6/20126/7/20126/7/2012 1:56:04 PMPPASS
Gene Phone #: ###-#### p/s o/h rec ok
ELE12-01348 Electrical Rough-In6/7/20126/7/20126/7/2012 1:07:54 PMPCANC
Please do an early pm inspection so that IP will turn power back on today. If you have questions, please call Kyle @ ###-#### or Andy @ ###-####. Phone #: ###-#### >> Inspection requested via web by Amie Rose see added p/s request
ELE12-01348 Permanent Service6/7/20126/7/20126/7/2012 1:07:18 PMPPASS
Please do an early pm inspection so that IP will turn power back on today. If you have questions, please call Kyle @ ###-#### or Andy @ ###-####. Phone #: ###-#### >> Inspection requested via web by Amie Rose p/s o/h rec. ok
ELE12-01349 Permanent Service6/7/20126/7/20126/7/2012 12:22:59 PMAPASS
BOB Phone #: ###-#### p/s o/h rec. ok
ELE12-01346 Electrical Rough-In6/7/20126/7/20126/7/2012 11:41:26 AMAPASS
wire ac Phone #: ###-#### >> Inspection requested via web by PAT MILLER
ELE12-01346 Final6/7/20126/7/20126/7/2012 11:41:19 AMAPASS
wire ac Phone #: ###-#### >> Inspection requested via web by PAT MILLER
ELE12-01338 Rough-In Permanent Service6/6/20126/7/20126/7/2012 11:41:00 AMAPASS
Call Dene with any questions
Thank you Phone #: ###-#### >> Inspection requested via web by kim grundhauser r/i p/s u/g new ok
ELE12-00870 Final6/6/20126/7/20126/7/2012 11:40:32 AMAPASS
>> Inspection requested via web by Stephanie White
ELE12-00724 Final6/7/20126/7/20126/7/2012 10:12:06 AMAPASS
THANKS Phone #: ###-#### >> Inspection requested via web by Bob Glenn
called clearence MB closet fixture contr. will address violation and correct it
GCE12-00011 GCE-Final6/6/20126/7/20126/7/2012 9:46:04 AMAPASS
Kevin @ ###-####
BLD Final completed
ok called needs to remove temp. cord on 30 amp 2 pole and install cover. I put cover on with 2 screws so panel is covered. final ok no card
ELE12-01340 Rough-In Permanent Service6/6/20126/7/20126/7/2012 7:58:55 AMANR
Brandon is the electrician. Ready to final. Phone #: ###-#### >> Inspection requested via web by joel smith talked with contr they will request inspection when ready