Inspections for the day of: Thursday, June 8, 2006.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-00807 Final6/8/20066/8/20066/8/2006 4:36:37 PMPPASS
ELE06-02095 Electrical Rough-In6/8/20066/8/20066/8/2006 4:19:03 PMPPART
rick ###-#### u/g for sump pump
ELE06-00422 Electrical Rough-In6/8/20066/8/20066/8/2006 3:41:54 PMPPASS
this is for a ceiling inspection, any questions please call Steve Nuxoll; Phone #: ###-#### Internet Inspection Request from: Jeff Radford all ceilings 2nd floor east end ok
ELE06-01593 Permanent Service6/8/20066/8/20066/8/2006 3:00:23 PMPPASS
Might call before to gain access.; Phone #: ###-#### Internet Inspection Request from: Robert Murray p/s o/h rec. ok
ELE06-02082 Final6/8/20066/8/20066/8/2006 1:42:33 PMPCANC
brian; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley not ready general contractor called in on elect. contr permit told him that is a no no
ELE06-01761 Electrical Rough-In6/8/20066/8/20066/8/2006 1:41:12 PMPPASS
moorey; Phone #: ###-#### Note: pool house - dressing room pump hse - 2 bld Internet Inspection Request from: Cathy Chiles walls and ceiling ok restrm
ELE06-01203 Electrical Rough-In6/8/20066/8/20066/8/2006 1:02:27 PMPPART
need ceiling inspection in break room. thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH
ceiling ok
ELE05-03803 Electrical Rough-In6/8/20066/8/20066/8/2006 12:10:46 PMPPART
part r/i was done 06-07-06 in the PM when I was out there for electrical contractor r/i
ELE06-00772 Final6/7/20066/8/20066/8/2006 12:09:11 PMAFAIL
code= 1000; Phone #: ###-#### Internet Inspection Request from: William Zerfas corr. called left message, 210.52(A,B) (C)(1) outlet for wall spce and countertop kit
ELE06-01836 Final6/7/20066/8/20066/8/2006 10:27:39 AMAFAIL
CORRECTIONS MADE - READY FOR INSPECTION ON SPA. THANKS; Phone #: ###-#### Internet Inspection Request from: Barry Kendall corr. called stills needs to bond soffit vent
ELE06-01262 Final6/7/20066/8/20066/8/2006 10:02:07 AMAFAIL
LOS BETOS RESTAURANT IS READY FOR FINAL INSPECTION. THANKS; Phone #: ###-#### Internet Inspection Request from: Barry Kendall corr. called left message110.3(B) use manufactures breakers only, 408.4 panel directory, 314.23 secure box floor middle of kit., 210.62 needs show window outlets there is a sign already hanging with no power for itin the window, 210.8(B)(2) gfci for kit,and front couter area with sink, BCC no violations to be retained, note is all equipment at site and wired what are blanked boxes for?
ELE06-02072 Permanent Service6/7/20066/8/20066/8/2006 9:24:12 AMAPASS
this is for a 100 amp service change will be at address at 8:am call with approximate time. joe; Phone #: ###-#### Internet Inspection Request from: joe wheeler
p/s o/h rec. ok
ELE06-02072 Final6/8/20066/8/20066/8/2006 9:23:43 AMAPASS
this is for a 100 amp service change will be at address at 8:am call with approximate time. joe; Phone #: ###-#### Internet Inspection Request from: joe wheeler
survey posted needs #10 grd for 1/2" dryer flex, tighten locknut
ELE06-02104 Electrical Rough-In6/7/20066/8/20066/8/2006 8:12:07 AMAPART
Ufer inspection Thurs day please call me if any problems; Phone #: ###-#### Internet Inspection Request from: Don Lustig electrode ok
ELE05-03535 Final6/8/20066/8/20066/8/2006 12:00:00 AMPCANC
alex - call prior to insp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley - homeowner canceled 12:01 p.m.