ELE06-00435
| Final | 6/8/2006 | 6/8/2006 | 6/8/2006 4:26:59 PM | P | PASS |
|
|
looked at sign, ok to final
|
ELE06-02030
| Temporary Service | 6/8/2006 | 6/8/2006 | 6/8/2006 4:23:33 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 6/8/2006 at 7:51:11 AM. Contact: ###-####. t/s u/g n ok
|
ELE06-02068
| Rough-In Permanent Service | 6/8/2006 | 6/8/2006 | 6/8/2006 4:13:00 PM | P | PASS |
|
|
spencer; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ric ok, p/s u/g n ok
|
ELE06-00815
| ELE-Aging Inspection | 6/8/2006 | 6/8/2006 | 6/8/2006 3:50:14 PM | | NR |
|
|
no signs
|
ELE06-02090
| Electrical Rough-In | 6/7/2006 | 6/8/2006 | 6/8/2006 3:49:00 PM | P | CANC |
|
|
###-#### - shawn wrong request, see rip
|
ELE06-02090
| Rough-In Permanent Service | 6/7/2006 | 6/8/2006 | 6/8/2006 3:48:16 PM | P | PASS |
|
|
###-#### - shawn ric ok p/s u/g n ok
|
ELE06-00790
| Final | 6/8/2006 | 6/8/2006 | 6/8/2006 2:44:36 PM | P | PASS |
|
|
Call Mike w/ Doherty @ ###-#### for questions. Scheduled by Heather w/ Doherty; Phone #: ###-#### Internet Inspection Request from: Heather Packer ok to final, signed occ card
|
ELE05-04614
| Final | 6/8/2006 | 6/8/2006 | 6/8/2006 2:00:22 PM | P | PASS |
|
|
chris - reinsp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr made, ok to final
|
ELE06-02106
| Final | 6/8/2006 | 6/8/2006 | 6/8/2006 1:38:05 PM | P | CANC |
|
|
Brenda ###-#### see p/s
|
ELE06-02106
| Permanent Service | 6/8/2006 | 6/8/2006 | 6/8/2006 1:37:39 PM | P | FAIL |
|
|
Brenda ###-#### talked w/ owner, left corr notice, nec 312.5 all conductors entering enclosures shall have abrasion protection, 408.4 circuit directory shall be provided, 590.6(B)(1)gfci protection shall be provided for 50A recpt
|
ELE06-02113
| Rough-In Permanent Service | 6/8/2006 | 6/8/2006 | 6/8/2006 1:01:29 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Todd Holbrook walls only ok to cover, p/s exst meter pak n ok
|
ELE06-01103
| Final | 6/7/2006 | 6/8/2006 | 6/8/2006 11:40:02 AM | A | PASS |
|
|
DREGRANGE; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
|
ELE06-00499
| Final | 6/7/2006 | 6/8/2006 | 6/8/2006 10:36:39 AM | A | PASS |
|
|
DREGRANGE; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
|
ELE06-00793
| ELE-Aging Inspection | 6/8/2006 | 6/8/2006 | 6/8/2006 10:23:31 AM | | DONE |
|
|
see final
|
ELE06-00793
| Final | 6/8/2006 | 6/8/2006 | 6/8/2006 10:22:28 AM | A | PASS |
|
|
looked at sign, ok to final
|
ELE06-02093
| Rough-In Permanent Service | 6/7/2006 | 6/8/2006 | 6/8/2006 10:01:45 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 6/7/2006 at 12:05:29 PM. Contact: ###-####. called contr, left corr notice, nec 250.56 rod electrode shall be augmented by additional electrode, Note: access required to panel, 300.4(A)&(D) edge of holes and nm cable shall be 1 1/4" from edge of framing member, 334.80 where more than 2 nm cables are bundled through hole to be draft stopped, they shall be derated, 314.16 boxes shall be sufficient size to provide free space for all conductors,314.20 boxes in combustible walls shall be flush with finished surface, 314.27 box shall be installed for luminaire(back door), BCC all make-up shall be done, Note: tub access shall be min 20" w x 15" h
|
ELE06-02071
| Final | 6/7/2006 | 6/8/2006 | 6/8/2006 9:25:11 AM | A | PASS |
|
|
bill ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie service ok, u/g ok corr made, ok to final
|
ELE06-02099
| Temporary Service | 6/7/2006 | 6/8/2006 | 6/8/2006 8:31:40 AM | A | FAIL |
|
|
###-#### - brandon called, left message, left corr notice, nec 312.5 all conductors entering enclosures shall have abrasion protection,110.14(A) connection of conductors to terminal parts shall ensure a thoroughly good connection, 110.3(B) listed or labelled equipment shall be installed and used in accordance with instructions
|