Inspections for the day of: Monday, June 8, 2015.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS15-00125 ELE-Conference6/5/20156/8/20156/8/2015 4:20:12 PMPFAIL
Work done without permits - contact homeowner Lester Phone #: ###-#### 210-11 (c) 3 bath outlets shall be a dedicated 20 amp circuit
210.8- All bathroom receptacles shall have GFCI protection.
Section 4-05-18 ELECTRICAL PERMIT REQUIRED
Before any person installs or alters any electrical wiring, equipment, apparatus or fixture, they shall file a permit application with the Electrical Section.
Exception: Emergency Work. If immediate alteration or installation of electrical wiring,
equipment, apparatus or fixtures is necessary for reasons of public safety and/or welfare and an electrical permit cannot first be obtained without further endangering the public safety and/or welfare, such alteration or installation may be made without first obtaining the electrical permit therefore but the required electrical permit shall be obtained during the next business day after such alteration or installation shall have been made.
MIS15-00125 ELE-Conference6/8/20156/8/20156/8/2015 4:01:58 PMPFAIL
Work done without permits - contact homeowner Lester Phone #: ###-#### 334-30 nm cable shall be supported with 12 in of a box 300.4 nm cable ran through bored holes shall maintain 1 1/4 from face of surface to protect from physical damage 300.5 (h) nm xcable shall enter boxes through busshed openings 110-14 electrical terminations shall be considered to be in a enclosure
ELE15-01094 Final6/8/20156/8/20156/8/2015 2:55:44 PMPPASS
Please call 30 mins prior to insp to gain access Phone #: ###-#### Inspection requested via web by Eric Brown Final ok
ELE15-01669 Temporary Service6/5/20156/8/20156/8/2015 1:58:41 PMPPASS
Ryan is the contact at ###-#### Over head temp pole to access the property the gate east of the temp pole is unlocked. Phone #: ###-#### Inspection requested via web by Tracy Robertson t/s o/h n ok
ELE15-01113 Final6/5/20156/8/20156/8/2015 1:58:28 PMAPASS
Phone #: ###-#### Inspection requested via web by Seth Stears Final ok
ELE15-01285 Electrical Rough-In6/8/20156/8/20156/8/2015 10:22:04 AMAPASS
underground 2 inch conduits for the sub panels Phone #: ###-#### Inspection requested via web by Karl Paige Underground from transformer to each tenant space rough in ok cover
ELE15-01543 Rough-In Permanent Service6/5/20156/8/20156/8/2015 9:58:00 AMAPASS
Cody is the onsite contact at ###-#### Phone #: ###-#### Inspection requested via web by Tracy Robertson Rough in ok cover p/s u/g n ok
ELE15-00601 Electrical Rough-In6/5/20156/8/20156/8/2015 9:35:10 AMAPASS
Ceiling inspection please Phone #: ###-#### Inspection requested via web by Celinda Winters Grid rough in ok cover
ELE15-01656 Conference6/3/20156/8/20156/8/2015 9:22:37 AMADONE
Jeffwould like as early as possible but could you please call with an approx meet time Phone #: ###-#### Discussed code requirements for kitchen remodel. Owner may locate some receptacles serving counter top below or on face of cab due to handicap individual living at residence. Min circuits for counter top, ratings of appl. determine whether dedicated or not.
ELE15-01687 Permanent Service6/5/20156/8/20156/8/2015 8:42:39 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Rohl p/s o/h rec ok
ELE15-01687 Final6/8/20156/8/20156/8/2015 8:42:19 AMPPASS
Phone #: ###-#### Inspection requested via web by Dan Rohl Service reconnect Final ok
ELE11-02817 ELE-Aging Inspection6/8/20156/8/20156/8/2015 6:35:14 AM DONE
Waiting on contractor