PLM14-01966
| PLM-Aging Inspection | 6/8/2015 | 6/8/2015 | 6/9/2015 4:13:29 PM | | PART |
|
|
no calls
|
PLM14-00050
| PLM-Aging Inspection | 6/8/2015 | 6/8/2015 | 6/8/2015 4:48:16 PM | | PASS |
|
|
no calls
|
PLM14-00041
| PLM-Aging Inspection | 6/8/2015 | 6/8/2015 | 6/8/2015 4:38:46 PM | | PART |
|
|
no calls
|
PLM15-00589
| Plumbing Rough-in | 6/8/2015 | 6/8/2015 | 6/8/2015 4:36:30 PM | P | FAIL |
|
|
Please come after 3:00 Thanks Phone #: ###-#### Inspection requested via web by Erin Whiting====Need pipe protection per UPC 313.9 at bottom plates where they are notched, other nail plates missing, support pex every 32". Test ok to pull. reschedule when ready.
|
MIS15-00125
| PLM-Conference | 6/5/2015 | 6/8/2015 | 6/8/2015 4:17:55 PM | P | PART |
|
|
Work done without permits - contact homeowner Lester Phone #: ###-####=====Master bath fixtures moved, does not appear plumbing inspections were done, possible issues from lav and water closet not vented per UPC, access to inside walls and floors would be needed to verify.
|
PLM15-01856
| Water and/or Sewer | 6/8/2015 | 6/8/2015 | 6/8/2015 3:59:55 PM | P | PASS |
|
|
Ready Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM15-01856
| DOC - Permit Finaled | 6/8/2015 | 6/8/2015 | 6/8/2015 3:59:28 PM | P | PASS |
|
|
|
PLM15-01418
| Final | 6/5/2015 | 6/8/2015 | 6/8/2015 3:59:04 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Erin Whiting
|
PLM15-00691
| Water and/or Sewer | 6/8/2015 | 6/8/2015 | 6/8/2015 2:19:19 PM | P | PASS |
|
|
Please contact Jim Vincent at ###-#### for access. If he isin''t available please call me at ###-####. Thanks. Phone #: ###-#### Inspection requested via web by Josh Johnson====final ok,
|
PLM15-00691
| DOC - Permit Finaled | 6/8/2015 | 6/8/2015 | 6/8/2015 2:15:07 PM | P | PASS |
|
|
|
PLM15-01823
| Plumbing Rough-in | 6/5/2015 | 6/8/2015 | 6/8/2015 1:54:49 PM | P | NR |
|
|
JOB # 18017. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes====Not ready
|
PLM15-01230
| Final | 6/8/2015 | 6/8/2015 | 6/8/2015 1:38:19 PM | P | PASS |
|
|
Homeowner or general contractor should be on site all day. Please call me with an questions. ###-####. Thanks. Phone #: ###-#### Inspection requested via web by Josh Johnson
|
PLM15-01765
| Sprinkler (Final) | 6/8/2015 | 6/8/2015 | 6/8/2015 1:29:27 PM | P | FAIL |
|
|
Robin Phone #: ###-####====DCVA needs to be certified.
|
PLM15-01817
| Water Softner Final | 6/8/2015 | 6/8/2015 | 6/8/2015 11:42:31 AM | P | PASS |
|
|
|
PLM15-01817
| Other | 6/5/2015 | 6/8/2015 | 6/8/2015 11:40:43 AM | A | PASS |
|
|
installing a water softener system the residence name is Wanda Lamb please give her a call let her know what time the inspections is. Thank You Phone #: ###-#### Inspection requested via web by Carrie Mosher====NOTE: do not glue abs to pvc in the future, transition glue is permitted for 1 joint at the sewer/drain connection only.
|
PLM15-01846
| Groundwork | 6/8/2015 | 6/8/2015 | 6/8/2015 11:36:42 AM | A | FAIL |
|
|
Please come after 11:00 Phone #: ###-#### Inspection requested via web by Erin Whiting====no plans onsite, backfill material other than whats on site will be needed as well.
|
PLM15-01789
| Sprinkler (Final) | 6/5/2015 | 6/8/2015 | 6/8/2015 10:34:15 AM | A | PASS |
|
|
Julian Phone #: ###-####
|
PLM15-01790
| Sprinkler (Final) | 6/5/2015 | 6/8/2015 | 6/8/2015 10:33:55 AM | A | PASS |
|
|
Julian Phone #: ###-####
|
PLM15-01842
| Water and/or Sewer | 6/5/2015 | 6/8/2015 | 6/8/2015 10:21:26 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Kirk Johns====Home owner says no work performed yet, reschedule when ready
|
PLM15-01820
| Water and/or Sewer | 6/4/2015 | 6/8/2015 | 6/8/2015 10:10:20 AM | A | PASS |
|
|
The work will be done and have the test on by early AM on Mon, 6/8. Phone #: ###-#### Inspection requested via web by Bruce Scott
|
PLM15-01820
| DOC - Permit Finaled | 6/8/2015 | 6/8/2015 | 6/8/2015 10:10:03 AM | P | PASS |
|
|
|
PLM15-01771
| Plumbing Rough-in | 6/5/2015 | 6/8/2015 | 6/8/2015 9:55:45 AM | A | PASS |
|
|
if questions call Chad @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
|
PLM15-01371
| Groundwork | 6/5/2015 | 6/8/2015 | 6/8/2015 9:26:26 AM | A | PART |
|
|
DAVID IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER=====car wash TD ok, in
|
PLM15-01809
| Plumbing Rough-in | 6/6/2015 | 6/8/2015 | 6/8/2015 9:04:23 AM | A | FAIL |
|
|
North door, right side of garage for entry Phone #: ###-#### Inspection requested via web by Scott Myers====WC vent must be 6" over flood level rim before horizontal offset per 905.3 UPC, Nail plates must extend 1.5" past OD of pipe per 313.9 UPC, please correct and reschedule.
|
PLM15-01230
| Water and/or Sewer | 6/8/2015 | 6/8/2015 | 6/8/2015 7:40:42 AM | P | CANC |
|
|
Contractors and or homeowners should be on site all day. Please call me at ###-#### with any questions. Thanks. Phone #: ###-#### >> Inspection requested via web by Josh Johnson Inspection cancelled from web by: Josh Johnson
|