Inspections for the day of: Monday, June 8, 2015.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02301 ELE-Aging Inspection6/8/20156/8/20156/9/2015 11:13:41 AM DONE
called phone number has been disc
ELE14-03012 Final6/8/20156/8/20156/8/2015 2:30:20 PMPPASS
Basement apartment final. Please call for access Phone #: ###-#### Inspection requested via web by Eric Brown nh called and left a message with contractor final ok
ELE15-01388 Final6/8/20156/8/20156/8/2015 1:45:14 PMPNH
Corrections made. If you can call me I will let you know how to get to the panel. It''s a maze to get to it. Thank you ###-#### Phone #: ###-#### Inspection requested via web by daniel bibikov no-one home
ELE15-01048 Electrical Rough-In6/8/20156/8/20156/8/2015 1:35:40 PMPPASS
Steve (homeowners brother) Phone #: ###-#### upstairs bath floor heat ok cover
ELE15-01399 Final6/5/20156/8/20156/8/2015 1:21:57 PMAPASS
AC micro-inverter system. No DC voltage.
Enphase M250 Micro-Inverters, that are CSA, IEEE-1547, and UL-1741 listed.
Ironridge Integrated Grounding System mid clamps, bonding straps and bonding lugs.
And 270 watt Suniva panels, ETL listed.

A single home run, in metal conduit, is ran from the solar array to the knife switch, located on the front of the house, directly under the solar array. From the knife switch to the breaker in sub panel, located in the mechanical room behind the wall where the knife switch is mounted. The solar breaker and the knife switch are permanently marked for solar, and the circuit numbers identified in the knife switch and on the panel schedule.

The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service grounding electrode in the same sub panel.

The sub panel is in the main house, so give the homeowner a call for access at 890.3118

Thanks guys Phone #: ###-#### Inspection requested via web by Ryan King final ok
ELE15-01055 Final6/8/20156/8/20156/8/2015 12:29:18 PMPPASS
call with questions thanks Phone #: ###-#### Inspection requested via web by Don Lustig final ok
ELE15-01634 Electrical Rough-In6/8/20156/8/20156/8/2015 9:43:59 AMAPASS
Go thru gate on left of house to patio double glass door is work area.
general should be on site.
kitchen dining lighting and outlets as needed to meet code. Phone #: ###-#### Inspection requested via web by Mike Cole kitchen and bath rough-in ik cover
ELE15-01691 Electrical Rough-In6/7/20156/8/20156/8/2015 9:20:11 AMAPASS
Phone #: ###-#### Inspection requested via web by Eddy Udry master bath rough-in ok cover
ELE15-01598 Electrical Rough-In6/5/20156/8/20156/8/2015 8:48:23 AMAPASS
Inspection for cover Phone #: ###-#### Inspection requested via web by steve ragan rough-in ok cover
ELE15-00832 Final6/5/20156/8/20156/8/2015 8:43:14 AMAPASS
Phone #: ###-#### Inspection requested via web by David Nelson final ok