ELE06-01166
| Final | 6/8/2006 | 6/9/2006 | 6/9/2006 3:53:13 PM | P | PASS |
|
|
mike - reinsp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok card signed called electrician and met with owner on cords for pendent fixtures for display
|
ELE05-04648
| Electrical Rough-In | 6/9/2006 | 6/9/2006 | 6/9/2006 3:51:43 PM | P | PASS |
|
|
john call prior to insp for access; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok
|
ELE06-02102
| Rough-In Permanent Service | 6/8/2006 | 6/9/2006 | 6/9/2006 2:01:23 PM | P | PASS |
|
|
SPA AND SERVICE UPGRADE; Phone #: ###-#### Internet Inspection Request from: Barry Kendall r/i p/s o/h rec. ok
|
ELE06-02102
| Final | 6/9/2006 | 6/9/2006 | 6/9/2006 2:00:54 PM | P | PASS |
|
|
SPA AND SERVICE UPGRADE; Phone #: ###-#### Internet Inspection Request from: Barry Kendall ok corr. made
|
ELE06-02115
| Permanent Service | 6/8/2006 | 6/9/2006 | 6/9/2006 1:37:22 PM | P | FAIL |
|
|
don; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr called 110.26(F)(2) shall remove phone equipment from below p/s, 230.28 phone cable shall be removed from service mast note final that was done on original permit , was with power electrician hooked up not ID power electrician never called for p/s on job
|
ELE05-04417
| Permanent Service | 6/9/2006 | 6/9/2006 | 6/9/2006 12:50:49 PM | P | PASS |
|
|
steve; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie p/s u/g new for house meter
|
ELE06-02116
| Rough-In Permanent Service | 6/8/2006 | 6/9/2006 | 6/9/2006 11:01:49 AM | A | PART |
|
|
UFER GROUND INSPECTION; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH ok
|
ELE06-01633
| Permanent Service | 6/8/2006 | 6/9/2006 | 6/9/2006 11:01:31 AM | A | PASS |
|
|
marvin - #114; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
p/s u/g for meter space #114
|
ELE06-00609
| Final | 6/8/2006 | 6/9/2006 | 6/9/2006 10:28:21 AM | A | PASS |
|
|
Ron; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles final ok no card, floor outlets will be completed on permit ele06-02123
|
ELE06-01578
| Electrical Rough-In | 6/8/2006 | 6/9/2006 | 6/9/2006 10:14:51 AM | A | PASS |
|
|
peter - call 1/2 hr prior for access; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley r/i ok needs #10 equip grd too grd heater bath rm
|
ELE06-01523
| Electrical Rough-In | 6/8/2006 | 6/9/2006 | 6/9/2006 9:59:45 AM | A | FAIL |
|
|
Internet Inspection Request from: Tyler Bowen corr. fee due called314.16 box fill ,314.43 screws in plastic boxes, 314.17(A&C) replace all boxes cutin and 2 gang with broken clamps, 210.70 needs fixture or fixtures too light stairs, 210.52(A) outlet spacing
|
ELE06-01930
| Permanent Service | 6/8/2006 | 6/9/2006 | 6/9/2006 8:43:51 AM | A | FAIL |
|
|
bill - reinsp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr. called 250.24(A)(5) remove GEC and isolate it form grounded bus in subpanels
|
ELE05-03535
| Final | 6/8/2006 | 6/9/2006 | 6/8/2006 2:23:27 PM | P | PASS |
|
|
Nickoli; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt final ok correction made by electrical contr. permit ele06-02117
|
ELE06-02117
| Final | 6/8/2006 | 6/9/2006 | 6/8/2006 2:22:11 PM | A | PASS |
|
|
###-#### - allen only responsible for correcting the violations posted too owner's permit ele05-03535 final ok
|