Inspections for the day of: Friday, June 9, 2006.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorWilliam E Thomas
TitleELE-INSPECTOR
Phone #794-9492
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-02088 Electrical Rough-In6/9/20066/9/20066/9/2006 5:01:07 PMPPASS
mike - reinsp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
1. ri ok
2. p/s u/g n ok per insp #370
ELE06-01953 Rough-In Permanent Service6/9/20066/9/20066/9/2006 4:56:27 PMPPASS
Scheduled by a contractor via Hello! on 6/9/2006 at 10:16:22 AM. Contact: ###-####.
1. ri ok
2. p/s u/g n ok
ELE06-01244 Rough-In Permanent Service6/9/20066/9/20066/9/2006 3:38:11 PMPPASS
bob; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
ri ok
p/s u/g n ok
ELE06-01241 Rough-In Permanent Service6/9/20066/9/20066/9/2006 3:37:47 PMPPASS
bob; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
ri ok
p/s u/g n ok
ELE05-03715 Final6/8/20066/9/20066/9/2006 2:29:25 PMAPASS
Phone #: ###-#### Internet Inspection Request from: Tina Payne
final ok
ELE06-01819 Electrical Rough-In6/9/20066/9/20066/9/2006 2:08:39 PMPPASS
Common area restroom cover inspection. There is no 'suite #', I will try and remove the suite number from this permit as majority of the work is being done in the 1st floor common area. Please contact Dan with any questions. Thank you; Phone #: ###-#### Internet Inspection Request from: Wendy Waters
1. 1st floor bathrooms/ janitor closet, cielings only ok to cover
ELE06-01730 Final6/8/20066/9/20066/9/2006 1:54:14 PMAPASS
tim; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
cieling ok
final ok
ELE06-02023 Electrical Rough-In6/9/20066/9/20066/9/2006 12:34:05 PMPFAIL
Shelly; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
1. 300.4A1-- nail plates thruoghout the house
ELE06-02023 Permanent Service6/9/20066/9/20066/9/2006 12:33:15 PMPPASS
Shelly; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
p/s u/g n ok
ELE06-02059 Permanent Service6/8/20066/9/20066/9/2006 11:50:37 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Dana Moyer
ELE06-02059 Electrical Rough-In6/8/20066/9/20066/9/2006 11:50:07 AMACANC
Phone #: ###-#### Internet Inspection Request from: Dana Moyer
ELE06-02059 Rough-In Permanent Service6/9/20066/9/20066/9/2006 11:49:33 AMPFAIL
Phone #: ###-#### Internet Inspection Request from: Dana Moyer
1. 110.26A1-- working clearences sub panel
2. 240.24D-- panel in closet
3. 300.4F-- bushings for sub panel
4. 314.17A-- broken box tabs nm
5. 314.17C-- 8" stapling for nm boxs
6. 300.4A1-- nail plates
7. 300.4D-- nm cable parallel to studs
8. B.C.C.-- All make up shall be complete prior to rough-in inspection.
ELE06-01997 Final6/8/20066/9/20066/9/2006 9:33:52 AMAPASS
david - in life’s kitchen; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley