ELE08-00580
| ELE-Aging Inspection | 6/9/2008 | 6/9/2008 | 6/10/2008 4:02:07 PM | | NH |
|
|
no esc permit no signs yet
|
ELE08-01531
| Temporary Service | 6/9/2008 | 6/9/2008 | 6/9/2008 4:00:25 PM | P | PASS |
|
|
jerod Phone #: ###-#### T/S O/H Ok
|
ELE08-01547
| Electrical Rough-In | 6/9/2008 | 6/9/2008 | 6/9/2008 3:31:51 PM | P | PASS |
|
|
Anser Idaho is ready for extended circuit inspection in classroom, See Susanne Burton with any questions Phone #: ###-#### Internet Inspection Request from: gary batten no esc permit
|
ELE08-01547
| DOC - Permit Finaled | 6/9/2008 | 6/9/2008 | 6/9/2008 3:31:27 PM | P | PASS |
|
|
|
ELE07-03345
| Final | 6/9/2008 | 6/9/2008 | 6/9/2008 3:05:05 PM | P | FAIL |
|
|
Please call homeowner before for access to kitchen only inspection. Name: Terri Robinson - ###-####. Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson receps on the side of the kitchen with the appliance garage has all 3 lights on my tester lit and won't trip gfci recep.
|
ELE08-01530
| Electrical Rough-In | 6/7/2008 | 6/9/2008 | 6/9/2008 2:42:25 PM | P | PART |
|
|
trench inspection, underground feed to house approval to cover. Phone #: ###-#### Internet Inspection Request from: Andy Derrick underground ok to cover no esc permit
|
ELE08-01530
| Permanent Service | 6/9/2008 | 6/9/2008 | 6/9/2008 2:41:35 PM | P | PASS |
|
|
trench inspection, underground feed to house approval to cover. Phone #: ###-#### Internet Inspection Request from: Andy Derrick P/S O/H N Ok
|
ELE08-01200
| Rough-In Permanent Service | 6/9/2008 | 6/9/2008 | 6/9/2008 1:48:28 PM | P | PASS |
|
|
mike Phone #: ###-####
R/I Ok P/S U/G N Ok
|
ESC08-00236
| Random Inspection | 6/9/2008 | 6/9/2008 | 6/9/2008 1:40:51 PM | P | PART |
|
|
they were cleaning the street and sidewalk when i was there
|
ESC07-01370
| Random Inspection | 6/9/2008 | 6/9/2008 | 6/9/2008 12:51:21 PM | P | PASS |
|
|
looked good
|
ELE08-01483
| Electrical Rough-In | 6/8/2008 | 6/9/2008 | 6/9/2008 12:49:55 PM | A | PART |
|
|
Several trades are utlizing a common trench that blocks access to the job. The GC is asking that we have your inspection between 11am and 12pm. All trades will be installing conduit as they trench and this will not be ready before 11am but will need to be closed up soon after 12pm for job access. Phone #: ###-#### Internet Inspection Request from: janet johnson partial u/g ok to cover with spacing and bedding first. plan on site
|
ELE08-00980
| Final | 6/6/2008 | 6/9/2008 | 6/9/2008 9:14:24 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Celinda Winters box in cabinet shall be flush and GFCI protect bath fans in shower areas plans on site and no esc permit
|