Inspections for the day of: Monday, June 9, 2008.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Kinnear
TitleELE-INSPECTOR
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-01472 Electrical Rough-In6/9/20086/9/20086/9/2008 4:29:08 PMPPASS
larry - as early as possible please Phone #: ###-#### ok cover ri note esc permit on project
ELE08-01545 Electrical Rough-In6/9/20086/9/20086/9/2008 4:28:16 PMPPASS
Jim- uffer Phone #: ###-#### ok cover concrete encased electrode
ESC08-00139 General Inspection6/9/20086/9/20086/9/2008 3:37:37 PMPPART
sign posted & cobles at entry
ELE08-01533 Temporary Service6/6/20086/9/20086/9/2008 3:35:23 PMPNR
Chris Phone #: ###-#### t/w chris location of t/s is a long was away from job site. old temp needs work 240 volt brker gfci protected, grounding conductor needs plastic connector to enter box, & grounding wire to 120 volt outlet needs to be bare or green wire
ELE08-01538 Temporary Service6/9/20086/9/20086/9/2008 2:10:19 PMPPASS
contact: Bob Schroder Phone #: ###-#### Internet Inspection Request from: Julie Schroder t/s u/g n ok note no esc permit on project
ELE08-00482 Final6/9/20086/9/20086/9/2008 12:15:01 PMPPASS
Scheduled by a contractor via Hello! on 6/9/2008 at 8:46:38 AM. Contact: ###-####. ok final note no card availble to sign
ESC07-01532 General Inspection6/9/20086/9/20086/9/2008 12:13:46 PMPPASS
landscaping completed looks fine
ELE08-00560 Final6/9/20086/9/20086/9/2008 9:49:12 AMAPASS
ok final wall sign
ELE08-01536 Electrical Rough-In6/6/20086/9/20086/9/2008 9:44:10 AMAFAIL
kyle Phone #: ###-#### need to us approved disconnect not fuse holders also need to get right addressing for same side of street. note no esc permit.
ELE08-01129 Final6/6/20086/9/20086/9/2008 9:01:39 AMAFAIL
owner will be home Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe called contractor, left correction notice, NEC 225.30 each building shall be supplied by only 1 feeder or branch circuit, 250.32 shall install grounding electrode system for greenhouse, 352.30(A) shall secure rnc within 3' of termination, 250.24(A) grounding electrode conductor shall be connected to grounded service conductor, 310.8(D) cables shall be listed as sunlight resistant
ELE07-02247 DOC - Permit Expired6/9/20086/9/20086/9/2008 7:34:46 AMPPASS
no access DOC expire