ELE10-01229
| Electrical Rough-In | 6/9/2010 | 6/9/2010 | 6/9/2010 2:49:30 PM | P | PART |
|
|
Eric Phone #: ###-#### ok to cover 2 floor boxes ne part
|
ELE09-01423
| Final | 6/9/2010 | 6/9/2010 | 6/9/2010 2:23:07 PM | P | FAIL |
|
|
Inspection requested from web by: Brandon Blackham Phone #: ###-#### called, left message, left correction notice, NEC210.52(C)(1) receptace shall be nmounted within 24" of sink edge, 210.52(A)(2)(3) shall provide convenience receptacles below bar type counter, 314.20 shall provide cover for box in utility room, NOTE corrections shall be made within 5 working days or further action will be taken
|
ELE10-01244
| Electrical Rough-In | 6/7/2010 | 6/9/2010 | 6/9/2010 1:28:06 PM | P | FAIL |
|
|
Inspection requested from web by: Louis Keller Phone #: ###-#### called, left correction notice, NEC 312.5 all conductors entering enclosures shall have abrasion protection, 408.4 shall provide circuit directory that is clear, concise and explanatory, 110.22(A) shall identify disconnects and be durable enough to withstand the environment, 110.26 shall provide work space about sub-panel in garage
|
ELE10-00955
| Permanent Service | 6/8/2010 | 6/9/2010 | 6/9/2010 12:28:38 PM | P | NR |
|
|
Phone #: ###-#### called, said to call when done
|
ELE10-01257
| Conference | 6/8/2010 | 6/9/2010 | 6/9/2010 11:35:43 AM | A | DONE |
|
|
Phillip Phone #: ###-#### - call 30 mins prior to going talked about wiring remodel area, code items, when to call for ri inspection
|
ELE10-01218
| Final | 6/8/2010 | 6/9/2010 | 6/9/2010 10:42:37 AM | A | PASS |
|
|
david Phone #: ###-#### ok to final
|
ELE10-01251
| Permanent Service | 6/8/2010 | 6/9/2010 | 6/9/2010 10:37:24 AM | P | CANC |
|
|
Inspection requested from web by: TOM BICANDI Phone #: ###-#### Inspection cancelled from web by: TOM BICANDI
|
ELE10-01261
| Electrical Rough-In | 6/8/2010 | 6/9/2010 | 6/9/2010 10:19:08 AM | A | PASS |
|
|
well be ready after 10:00 Inspection requested from web by: Roy Kay Phone #: ###-#### ric ok
|
ELE10-00612
| Final | 6/8/2010 | 6/9/2010 | 6/9/2010 9:54:09 AM | A | PASS |
|
|
Please call first for lock box code. final service and downstairs repairs. Inspection requested from web by: Steve Ruter Phone #: ###-#### called, ok to final
|
ELE10-01256
| Temporary Service | 6/8/2010 | 6/9/2010 | 6/9/2010 9:18:03 AM | A | PASS |
|
|
THANKS, BOB Inspection requested from web by: Bob Glenn Phone #: ###-#### t/s u/g n ok
|
ELE10-01237
| Rough-In Permanent Service | 6/8/2010 | 6/9/2010 | 6/9/2010 8:36:10 AM | A | PASS |
|
|
Inspection requested from web by: Zane Robertson Phone #: ###-#### corrections made, ric ok, p/s u/g n ok
|
ELE10-00991
| Final | 6/8/2010 | 6/9/2010 | 6/9/2010 8:04:48 AM | A | PASS |
|
|
bruce Phone #: ###-#### ok to final
|
ELE09-01437
| Final | 6/9/2010 | 6/9/2010 | 6/9/2010 7:23:08 AM | A | PASS |
|
|
ok to final
|
ELE07-01553
| ELE-Aging Inspection | 6/9/2010 | 6/9/2010 | 6/9/2010 7:20:42 AM | | DONE |
|
|
see doc expire
|
ELE07-01553
| DOC - Permit Expired | 6/9/2010 | 6/9/2010 | 6/9/2010 7:20:30 AM | A | PASS |
|
|
no activity
|
ELE07-01238
| ELE-Aging Inspection | 6/9/2010 | 6/9/2010 | 6/9/2010 7:19:25 AM | | DONE |
|
|
see doc expire
|
ELE07-01238
| DOC - Permit Expired | 6/9/2010 | 6/9/2010 | 6/9/2010 7:19:13 AM | A | PASS |
|
|
no activity
|