Inspections for the day of: Tuesday, June 9, 2020.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04088 Final6/9/20206/9/20206/9/2020 4:18:21 PMPPASS
Screened-David Phone #: ###-####
- final ok
MEC20-02087 Final6/8/20206/9/20206/9/2020 3:33:46 PMPPASS
Please have inspector call owner Danna when in route to home ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd
- A/C coil only co ok
MEC20-02313 Final6/9/20206/9/20206/9/2020 3:15:51 PMPFAIL
We roughed this in about 2 years ago. We had rough-in inspection on ductwork and furnace and a/c back then. furnace is in attic. Phone #: ###-#### Inspection requested via web by max sanders
- platform in attic needs extended in front of furnace. Owner says he will take of this corrections
- bvent needs 1" clearances
- condensate line needs extended down to ground level outside
- need a 20lb gas test
- line set insulation in attic needs repaired
MEC20-02083 Final6/4/20206/9/20206/9/2020 2:43:15 PMPNH
Call ahead to Hannah when headed to the residence - 2818 and 2820 are right next to each other so maybe they can be done at the same time Phone #: ###-#### Inspection requested via web by Sarah Small
- no access
- need electrical permit issued
MEC20-02084 Final6/4/20206/9/20206/9/2020 2:41:56 PMPFAIL
Call ahead to Hannah when headed to the residence - 2818 and 2820 are right next to each other so maybe they can be done at the same time Phone #: ###-#### Inspection
requested via web by Sarah Small
- mini split final ok
- need to see electrical permit issued
MEC20-02228 Final6/4/20206/9/20206/9/2020 2:21:04 PMPPASS
Field super: Chad Robertson
homeowner: Kari Moggridge Phone #: ###-#### Inspection requested via web by Lisa Whitney
- furnace ac coil co ok
MEC20-02293 Final6/8/20206/9/20206/9/2020 2:14:20 PMPPASS
Please inspect after 2:30. Julie Hendricks ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- A/C coil only co ok
MEC20-02274 Final6/8/20206/9/20206/9/2020 1:19:04 PMPPASS
Field super: Chad Robertson
Owner: Randy and Andrea Blades ###-#### Phone #: ###-#### Inspection requested via web by Lisa Whitney
- furnace ac coil co ok
MEC20-02288 Rough-in6/9/20206/9/20206/9/2020 11:04:56 AMANR
Please call contractor 30 minutes in advance for access at ###-#### and call Ryan with questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum
- not ready
- fireplace venting needs finished and need to have installation instructions onsite. Gas shut off valve for fireplace needs access
- couldn't find gas pressure test
- add dryer venting to permit
MEC20-02041 Rough-in6/8/20206/9/20206/9/2020 10:40:40 AMAPASS
Please call Josh Moran prior to arrival at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
- R/I hvac only
DO NOT COVER until all mech work has been seen
- fireplace needs permit issued by installers and inspected
- water heater flue will need inspected
- adjust permit details to reflect work being done
bathroom exhaust, range, dryer vent
- electric heat will need to be verified to man J and is being done by others
MEC20-02041 Pressure Test6/8/20206/9/20206/9/2020 10:36:45 AMAPASS
Please call Josh Moran prior to arrival at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
- 20lb gas test ok
- tagged meter location
MEC20-01957 Final6/8/20206/9/20206/9/2020 9:53:03 AMAPASS
Mechanical Final Inspection needed for Loomis please call Karl at ###-#### thank you. Phone #: ###-#### Inspection requested via web by Karl Hestekin
- final ok
- occ card signed
MEC20-02152 Rough-in6/8/20206/9/20206/9/2020 9:12:34 AMAFAIL
TYLER ###-####
EMAILS SENT TO JACK REYNOLDS AND BRIAN SCOLES. PLEASE REFERENCE Phone #: ###-#### Inspection requested via web by Mike Almanza
- need to see 10" non combustible material installed above fireplace for R/I
- will need to see factory safety barrier installed on fireplace for clearace reduction of mantel by final
MEC19-05004 Mec-Aging Inspection6/9/20206/9/20206/9/2020 8:30:09 AM FAIL
Permit has not been active since being issued on 11-5-19. Schedule inspection with owner if work is finished. Permit will expire at next mechanical aging inspection if not active.
MEC19-05021 Mec-Aging Inspection6/9/20206/9/20206/9/2020 8:29:44 AM FAIL
Permit has not been active since being issued on 11-6-19. Schedule inspection with owner if work is finished. Permit will expire at next mechanical aging inspection if not active.
MEC20-02291 Final6/8/20206/9/20206/9/2020 6:55:38 AMPCANC
INSTALLER GERRY ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
MEC20-02291 Pressure Test6/8/20206/9/20206/9/2020 6:55:36 AMPCANC
INSTALLER GERRY ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
MEC20-02190 Final6/2/20206/9/20206/3/2020 7:56:05 AMPCANC
INSTALLER DUSTIN ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt