Inspections for the day of: Monday, July 1, 2002.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD00-03428 BLD-Framing/Rough-in6/28/20027/1/20027/1/2002 12:00:00 AMAFAIL
calvin-- ###-####--fr basement walk through maintane firewall deflection track top of wall and gyp. isi needs listings to address penatrations. 7/1/2002 11:41:03 AM
BLD02-00176 BLD-Framing/Rough-in6/28/20027/1/20027/1/2002 12:00:00 AMAPART
r/i- shirley- ###-####exterior gyp ok for cover. 7/1/2002 8:43:33 AM
BLD02-01162 BLD-Framing/Rough-in6/28/20027/1/20027/1/2002 12:00:00 AMAPASS
DAVE ###-#### DAVE ###-####final 7/1/2002 8:28:22 AM
BLD02-01160 BLD-Framing/Rough-in6/28/20027/1/20027/1/2002 12:00:00 AMAPASS
DAVE ###-#### final 7/1/2002 8:28:27 AM
BLD02-01161 BLD-Framing/Rough-in6/28/20027/1/20027/1/2002 12:00:00 AMAPASS
DAVE ###-#### final. 7/1/2002 8:28:46 AM
BLD02-00729 BLD-Final6/27/20027/1/20027/1/2002 12:00:00 AMAPASS
TOM ###-#### ok pending p&z sign off 7/1/2002 11:39:28 AM
BLD02-00978 BLD-Final6/28/20027/1/20027/1/2002 12:00:00 AMPFAIL
###-#### ###-####previous c/n not done. 7/1/2002 1:05:56 PM
BLD02-01520 BLD-Footing7/1/20027/1/20027/1/2002 12:00:00 AMPPASS
###-#### mike ft ok as per approved plan. 7/1/2002 1:47:25 PM
BLD01-02848 BLD-Framing/Rough-in7/1/20027/1/20027/1/2002 12:00:00 AMPPART
les- ###-####fr inspclean rm ceilling grid ok/ fire wall at rain leader needs patch at unastrut and chec pipe penatration. 7/1/2002 3:45:03 PM
BLD02-00880 BLD-Framing/Rough-in7/1/20027/1/20027/1/2002 12:00:00 AMPFAIL
1. ALTERNATE WALL PANEL FOR ONE STORY - Any braced wall panel, in one-story buildings, may be replaced by an alternate braced wall panel having the following features: (1) each panel shall have a length of not less than 2 feet 8 inches and a height of not more than 10 feet, (2) each panel shall be sheathed on one face with 3/8-inch-minimum-thichness plywood sheathing nailed with 8d common or galvanized box nails spaced 6 inches on center at the edges and 12 inches at intermediate supports, (3) all plywood edges are blocked, (4) two 1/2 inch anchor bolts with properly sized nuts and washers and imbedded at least 7 inches into the concrete are provided at panel quarter points, (5) each panel end stud shall have a tie-down device, installed in accordance with the manufacturer's recommendations, fastened to the foundation and capable of providing an approved uplift capacity of not less than 1,800 pounds, (6) the panels shall be supported directly on a foundation or on floor framing supported directly on a foundation which is continuous across the entire length of the braced wall line, and (6) the foundation is reinforced with not less than one No. 4 bar top and bottom. (1997 UBC 2320.11.4)
BLD02-00881 BLD-Framing/Rough-in7/1/20027/1/20027/1/2002 12:00:00 AMPFAIL
1. ALTERNATE WALL PANEL FOR ONE STORY - Any braced wall panel, in one-story buildings, may be replaced by an alternate braced wall panel having the following features: (1) each panel shall have a length of not less than 2 feet 8 inches and a height of not more than 10 feet, (2) each panel shall be sheathed on one face with 3/8-inch-minimum-thichness plywood sheathing nailed with 8d common or galvanized box nails spaced 6 inches on center at the edges and 12 inches at intermediate supports, (3) all plywood edges are blocked, (4) two 1/2 inch anchor bolts with properly sized nuts and washers and imbedded at least 7 inches into the concrete are provided at panel quarter points, (5) each panel end stud shall have a tie-down device, installed in accordance with the manufacturer's recommendations, fastened to the foundation and capable of providing an approved uplift capacity of not less than 1,800 pounds, (6) the panels shall be supported directly on a foundation or on floor framing supported directly on a foundation which is continuous across the entire length of the braced wall line, and (6) the foundation is reinforced with not less than one No. 4 bar top and bottom. (1997 UBC 2320.11.4)